Operation Manual / A150-M58/68
7 Periodic maintenance work / 7.4 Cleaning components mechanically
Fig. 33: Diffuser
79000
Compressor casing
01
Diffuser surfaces
02
Diffuser annulus
03
Slots
All of the surfaces on the diffuser must be free of contamination after cleaning. In the
u
case of slotted diffusers, this applies in particular to the diffuser slots (03) and the dif-
fuser annulus (02).
Cleaning procedures should be selected that do not result in removal of the diffuser's
u
base material or damage to its surfaces.
The evenness of all surfaces (01) between the diffuser blades must be checked visually.
u
The surfaces must be flat and even. Any deformations or deteriorations of the surface
caused by the cleaning process are not permitted.
Have damaged diffusers replaced by a Turbo Systems service station.
u
7.4.4
Turbine-end, non-rotating parts
WARNING
Handling operating materials and supplies
Swallowing or inhaling vapours of operating materials and supplies or con-
tact with them may be harmful to health.
Do not breathe in these substances and avoid contact with the skin.
u
Ensure proper ventilation.
u
Observe the information in the material safety data sheet for the operat-
u
ing materials and supplies.
Wear personal protective equipment (PPE) according to the material
u
safety data sheet.
Comply with local legislation.
u
Wear safety goggles.
Wear safety gloves to protect against chemical hazards.
Wear a respiratory mask to protect against gases.