Download Print this page
FITNESS AUDIO DX6-DR Operation Manual

FITNESS AUDIO DX6-DR Operation Manual

Dual-channel three redundancy digital wireless microphone system

Advertisement

Quick Links

DX6-DR / DX6-TF
Operation manual
Dual-Channel Three Redundancy Digital
Wireless Microphone System

Advertisement

loading
Need help?

Need help?

Do you have a question about the DX6-DR and is the answer not in the manual?

Questions and answers

Summary of Contents for FITNESS AUDIO DX6-DR

  • Page 1 DX6-DR / DX6-TF Operation manual Dual-Channel Three Redundancy Digital Wireless Microphone System...
  • Page 2 DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System Important safety instructions ◼ READ, KEEP and HEED these instructions. ◼ CLEAN ONLY with dry cloth. ◼ DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer’s instructions.
  • Page 3: Important Usage Instructions

    Instructions Thank you for choosing FITNESS AUDIO digital wireless microphone system! For more details, please take a few moments to read this operating manual for thorough understanding of the function and operation of both transmitter and receiver. In the box...
  • Page 4 DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System Parts and functions of DX6-DR receiver Antenna A (SMA) Antenna B (SMA) CH 1 CH 2 2405 2456 M H z M H z SYNC SYNC Power switch MENU / SET button...
  • Page 5 Instructions Antenna installation Install supplied 2.4GHz receiver SMA antenna A and B at SMA connectors on the front panel. Please make sure the antennas being firmly tightened otherwise the reception quality might be affected.  Receiver placement 1. The receiver should be at least 1m above the ground and 1m away from a wall or metal surface to minimize reflections.
  • Page 6: Volume Adjustment

    DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System Channel synchronization of the receiver and transmitter Press and hold the transmitter’s synchronization button until “SYNC” flashes on the LCD.  Press and hold the receiver’s SYNC button until the LCD displays “-Sync-” and the channel number becomes the same as the transmitter indicative of successful channel synchronization.
  • Page 7 Instructions Setting microphone’s sensitivity from the receiver Press SET button to make the sensitivity level flashes SYNC → Press DOWN(▼) and UP(▲) button to adjust the sensitivity level between -1, 0 and 1. SYNC  After a level is chosen, wait about 5 seconds to save the setting and the level will not change after reboot until the setting is changed again.
  • Page 8: Notch Filter

    DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System Notch filter When noise signals are picked up by the microphone, notch filter can prevent these signals entering the receiver. Its default status is ON. If using belt-pack transmitter, it’s advised to turn on the notch filter.
  • Page 9 Instructions Equalizer setting Equalizer adjustment is actually used to increase or reduce the high/mid/low frequency component of the speaker's restored sound. It is so-called raising or attenuating treble/bass via frequency-specific volume controls to improve human voices or make musical instruments’ sound more prominent.
  • Page 10 DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System Audio output connection INDIVIDUAL balanced output MIXED unbalanced output ¼” PHONE PLUG connector provides unbalanced audio XLR connector provides balanced audio output signal output signal from this jack to the mixer/amplifier. Use an audio output cable with ¼”...
  • Page 11 Battery compartment Channel synchronization button Power button Charging contacts Audio input connector for FITNESS AUDIO headset / lavalier / earworn microphone. Battery installation & indicator This transmitter requires two AA batteries to operate. To install, remove the battery cover and insert the batteries into the compartment.
  • Page 12 DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System Channel synchronization of the receiver and transmitter Open the cover and hold the synchronization button until “SYNC” on the LCD flashes.  Hold the receiver’s SYNC button until the LCD displays “-Sync-” and the channel number becomes the same as the transmitter indicative of successful channel synchronization.
  • Page 13 Instructions Battery type setting Use MENU button to go to the BATTERY TYPE page.  Press and hold SET button until NiMH or AKLN flashes to denote readiness for setting.  Press SET button to select either NiMH (rechargeable battery) or AKLN (alkaline battery). ...
  • Page 14 DX6-DR / DX6-TF Dual-Channel Three Redundancy Digital Wireless Microphone System SCAN mode setting There are five scan modes for selection: A-SCAN, F-CH01, F-CH02, F-CH03 and F-CH04. Mode A-SCAN F-CH01 F-CH02 F-CH03 F-CH04 The microphone will automatically There are four modes for selection.
  • Page 15 Instructions MUSICRECEIVER POWER LINK ANT.

This manual is also suitable for:

Dx6-tf