Fusion One accurately blends proportioned chemical with water for cleaning, sanitizing or `needs.
The dispensing system uses a pilot drive water valve designed for easy maintenance. Fusion One is
engineered with 1055 approved back flow protect using DEMA's Air Gap or Action Gap proportioning
system.
Warnings
All installations must conform to local plumbing codes and use approved backflow prevention devices.
A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the
state of Wisconsin and any other state that requires the use of a pressure indicating tee.
ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL
PRODUCTS.
I-1305 Rev. N-47130
Fusion One
Installation and Setup Guide
9.23.2021
PAGE 1 OF 11

Advertisement

loading

Summary of Contents for DEMA Fusion One

  • Page 1 Fusion One accurately blends proportioned chemical with water for cleaning, sanitizing or `needs. The dispensing system uses a pilot drive water valve designed for easy maintenance. Fusion One is engineered with 1055 approved back flow protect using DEMA’s Air Gap or Action Gap proportioning system.
  • Page 2: Installation And Servicing

    Installation and Servicing WARNING: INSTALLATION OF DEMA PRODUCTS MUST MEET ALL APPLICABLE PLUMBING CODES AND REGULATIONS ESTABLISHED BY NATIONAL, CITY, COUNTY, PARISH, PROVINCIAL OR OTHER AGENCIES. IT IS POSSIBLE THAT PLUMBING CODES AND REGULATIONS REQUIRE THAT A CERTIFIED INSTALLATION CONTRACTOR OR ENGINEER PERFORM THE PLUMBING INSTALLATION.
  • Page 3 Note: Chemical containers cannot be greater than 6 feet (1.8M) below the Fusion One dispenser. 7. Install the Fusion One cover by positioning the top of the cover near the top of dispenser back plate and push the cover back over the valve assembly until the tab latches on side of the unit.
  • Page 4 Installation and Servicing Continued… 9: Removal of Button Tab to engage Locking Activation feature (for 4GPM Proportioners). Step 1: Remove Fusion One cover (see #2 above). Step 2: Break off tab with pliers. Fusion Cover – Rear View I-1305 Rev. N-47130 9.23.2021...
  • Page 5 Metering Tip Kits Table 1: Fusion Metering Tips 100.15K (Provided) 1 GPM Air Gap Proportioner 4 GPM Air Gap Proportioner Metering Tip Color Oz./gal ml/L Ratio : 1 Oz./gal ml/L Ratio : 1 1.37 10.57 93.65 0.37 2.91 343.19 Orange 1.67 12.91 76.48...
  • Page 6 Table 3: Fusion Metering Tips 100.15K (Provided) 1 GPM Action Gap Proportioner 4 GPM Action Gap Proportioner Metering Tip Color Oz./gal ml/L Ratio : 1 Oz./gal ml/L Ratio : 1 0.96 7.46 133.12 0.32 2.49 399.99 Orange 1.20 9.30 106.51 0.38 2.97 335.84...
  • Page 7 Replacement Parts: Fusion Unit Fusion One units can be connected together using the Fusion Valve Connector (41.186.1). It would replace the Plug Adapter (40.926.1) on one of the units, and the Inlet Adapter Assembly (40.925.1 & 40.925.2) of the other unit.
  • Page 8 Replacement Part: Fusion Unit Continued… FUSION REPLACEMENT PARTS Item No. DEMA Part No. DESCRIPTION 40.826.1 BASE, FUSION HK 40.970.1 FUSION BUBBLE LEVEL 44.116.3 #8 HI-LO SCREW X 1" LONG 40.847.2 FUSION VALVE ASSEMBLY (SEE PG. #7 FOR PARTS) 63.78 O-RING-SEAL EPT (7/16"I.D. X 3/8"O.D. X 1/16" NOM.) 40.853.1...
  • Page 9 Replacement Parts Valve Body VALVE REPLACEMENT PARTS Item No. DEMA Part No. DESCRIPTION 40.854.1 RETAINING CLIP PILOT ACTIVATED VALVE 41.058.1 DIAPHRAGM CAP O-RING SEAL EPDM (15/16” X 1/16”) 619.21 1-1/16" DIAPHRAGM 98.26.1 40.824.1 VALVE BODY 40.849.1 BUTTON, PILOT ACTIVATED VALVE O-RING SEAL (3/16"ID X 3/8"OD X 3/32"NOM.)
  • Page 10: Product Dimensions

    Product Dimensions FUSION ONE FUSION ONE FUSION ONE LEFT END VIEW FRONT VIEW RIGHT END VIEW I-1305 Rev. N-47130 9.23.2021 PAGE 10 OF 11...
  • Page 11: Specifications

    Rubber and synthetic rubber parts such as “o”-rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval DEMA, this warranty is void.