Blueridge BPHP14 Series Installation And Maintenance Instructions Manual

Blueridge BPHP14 Series Installation And Maintenance Instructions Manual

Residential packaged units air conditioners and heat pumps

Advertisement

Quick Links

THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
Installation and servicing of air conditioning equipment
can be hazardous due to internal refrigerant pressure
and live electrical components. Only trained and
qualified service personnel should install or service
this equipment. Installation and service performed by
unqualified persons can result in property damage,
personal injury, or death.
For your safety, do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance. Such actions could result in property
damage, personal injury, or death.
The installation of this appliance must conform to the requirements of the National Fire Protection Association; the
National Electrical Code, ANSI/NFPA No. 70 (latest edition) in the United States; the Canadian Electrical Code Part
1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws or local ordinances. Local authorities having
jurisdiction should be consulted before installation is made. Such applicable regulations or requirements take precedence
over the general instructions in this manual.
507296-01B
WARNING
WARNING
Save these instructions for future reference
INSTALLATION AND MAINTENANCE
INSTRUCTIONS
BPHP14 SERIES UNITS
RESIDENTIAL PACKAGED UNITS
Air Conditioners and Heat Pumps
507296-01B
12/2016

Table of Contents

Installation ...................................................................2
Electrical Wiring ...........................................................4
Duct System ................................................................5
Filters ...........................................................................5
Condensate Drain........................................................5
Sequence of Operation................................................7
Maintenance ................................................................9
Wiring Diagrams ........................................................10
If this unit is to be installed in a mobile or manufactured
home application, the duct system must be sized to
achieve static pressures within the manufacturer's
guidelines. All other installation guidelines must also
be followed. Failure to do so may result in equipment
damage, personal injury, and improper performance of
the unit.
*P507296-01B*
CAUTION
Issue 1650
WARNING
Manufactured By
Blue Summit LLC
8201 C National Turnpike
Louisville, KY 40214
(P) 507296-01B
Page 1 of 13

Advertisement

loading
Need help?

Need help?

Do you have a question about the BPHP14 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Blueridge BPHP14 Series

  • Page 1: Table Of Contents

    INSTALLATION AND MAINTENANCE INSTRUCTIONS BPHP14 SERIES UNITS RESIDENTIAL PACKAGED UNITS Air Conditioners and Heat Pumps 507296-01B 12/2016 Table of Contents Installation ..............2 THIS MANUAL MUST BE LEFT WITH THE Electrical Wiring ............4 HOMEOWNER FOR FUTURE REFERENCE Duct System ..............5 Filters ................5 WARNING Condensate Drain............5...
  • Page 2: Installation

    Location The unit is designed to be located outdoors with sufficient WARNING clearance for free entrance to the air inlet and discharge air openings. The location must also allow for adequate Improper installation, adjustment, alteration, service, service access. or maintenance can cause injury or property damage. Refer to this manual.
  • Page 3 Service Access Access to all serviceable components is provided by four removable panels: upper access panel (for blower, ID coil,   and optional filter), auxiliary heat access, control access   panel, and compressor access. WARNING This unit is charged with HFC-410A refrigerant. Operating pressures for units charged with HFC-410A are higher than pressures in units charged with HCFC- 22.
  • Page 4: Electrical Wiring

    Electrical Wiring Field-Supplied Fused Ground All field wiring must be done in accordance with National or Circuit Breaker Contactor Disconnect Electrical Code recommendations, local codes, and applicable requirements of UL Standards, or in accordance with Canadian Electrical Code recommendations, local codes, or CSA Standards.
  • Page 5: Duct System

    Duct System NOTE: Duct system should be designed and sized according to the methods in Manual Q of the Air Conditioning Contractors of The filter rack must be installed prior to installation of America (ACCA). the unit in applications where access to the rear panel is limited.
  • Page 6 Crankcase Heater (if used) Some models may be equipped with a crankcase heater to prevent excessive migration of liquid refrigerant into the Minimum Pitch: 1 in (25) Per 10” compressor during off cycles. Power must be maintained (3048 mm) of Unit to the unit to keep this feature active.
  • Page 7: Sequence Of Operation

    Sequence of Operation Cooling K1 RELAY When the thermostat is in the cooling mode, the O circuit is powered, which energizes the reversing valve. Upon Diagnostic LEDs cooling demand, the thermostat closes circuit R and Y. Defrost Interval Timing Pins TEST Closing R and Y closes the unit contactor, starting the K2 RELAY...
  • Page 8 A test option is provided for troubleshooting. The test mode • For the first 90 seconds each time the reversing valve may be started any time the unit is in the heating mode and switches heat/cool modes the defrost thermostat is closed or jumpered. If the jumper If the TEST pins are jumpered and the 5-minute delay is in the TEST position at power up, the control will ignore is being bypassed, the LO PS terminal signal is not...
  • Page 9: Maintenance

    Maintenance system charge, evacuate to 500 microns, and weigh in refrigerant to nameplate charge. It is critical that the exact charge is re-installed. Failure to comply will compromise WARNING system performance. Before performing maintenance operations on the If unit performance is still questionable, check for system, shut off all electrical power to the unit.
  • Page 10: Wiring Diagrams

    Wiring Diagrams Figure 8. Connections Diagram - A/C PSC Page 10 of 13 Issue 1650 507296-01B...
  • Page 11 Figure 9. Connections Diagram - A/C Constant Torque 507296-01B Issue 1650 Page 11 of 13...
  • Page 12 Figure 10. Connections Diagram - Heat Pump PSC Page 12 of 13 Issue 1650 507296-01B...
  • Page 13 Figure 11. Connections Diagram - Heat Pump Constant Torque 507296-01B Issue 1650 Page 13 of 13...