4.3. Disassembly for Inspection & Service
The extent of disassembly required will depend upon the extent of inspection and service
required.
Note: To avoid the risk of electric shock, turn off and unplug the
amplifier from the +12V power source before disassembly or
reassembly is attempted.
4.3.1.
Top Cover Removal
1. On a soft surface, turn the
amplifier over to view the
bottom. Using a T-25
screwdriver, remove the four
large Torx-head screws at
bottom corners. (Figure 4.1)
2. Turn the amplifier over to view
the top. Using a 5 /32 inch Allen
wrench, remove the four cap
head screws on the clear
plexiglas cover. (Figure 4.1)
3. Slide the plexiglas cover out.
4. Using a T-15 screwdriver and
remove the input cover and output
cover. Each cover is attached with 4
screws. (Covers not shown)
5. Using a T-15 screwdriver, remove
the four Torx-head screws in the top
cover around the output. (Figure 4.2)
6. Using a T-15 screwdriver, remove
the four Torx-head screws in the top
cover around the input. (Figure 4.2)
7. Carefully remove the cover
2003 Crown Audio, Inc.
Figure 4.1 Plexiglas Removal.
Figure 4.2 Top Cover Removal
A6000GTi Service Manual
Maintenance