hilscher PKV 30-IBS Device Manual

Protocol converter for interbus slave

Advertisement

Quick Links

Device manual
PKV 30-IBS
Protocol converter for InterBus slave
Hilscher Gesellschaft für Systemautomation mbH
Rheinstraße 78
D-65795 Hattersheim
Germany
Tel. +49 (0) 6190 / 9907 - 0
Fax. +49 (0) 6190 / 9907 - 50
Sales: +49 (0) 6190 / 9907 - 0
Hotline and Support: +49 (0) 6190 / 9907 - 99
e-mail: hilscher@hilscher.com
Homepage: http://www.hilscher.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PKV 30-IBS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for hilscher PKV 30-IBS

  • Page 1 Device manual PKV 30-IBS Protocol converter for InterBus slave Hilscher Gesellschaft für Systemautomation mbH Rheinstraße 78 D-65795 Hattersheim Germany Tel. +49 (0) 6190 / 9907 - 0 Fax. +49 (0) 6190 / 9907 - 50 Sales: +49 (0) 6190 / 9907 - 0 Hotline and Support: +49 (0) 6190 / 9907 - 99 e-mail: hilscher@hilscher.com...
  • Page 2 3 29.01.99 PKV 30-IBS 9715001 revision Although this appliance has been developed with great care and intensively tested, Hilscher Gesellschaft für Systemautomation mbH cannot guarantee the suitability of this appliance for any purpose not confir- med by us in writing.
  • Page 3: Table Of Contents

    3 Technical data ..................Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 4: Introduction

    The protocol converter PKV 30-IBS has two communications interfaces and one of them is for the remote bus InterBus and the other one is for the connection of the external decive to the PKV 30-IBS. These interface could be also used for diagnostic.
  • Page 5: General Device Description

    Valid operation and an error state from the serial interfaces are displayed by LEDs. Block diagram of the protocol converter PKV 30-IBS Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 6: Configuration

    Side viewing of PKV 30-IBS with jumper row selection jumper J2 interface open RS232 RS485 1-2, 3-4 RS422 4 3 2 Selection of serial interface type Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 7: Connection Of The Power Supply

    3-way COMBICON plug from PHOENIX (MSTB 2.5/3-ST-5.08) is used. symbol signal +24V +24V supply voltage reference potential earth ground Pin assignment of the X1 power supply connector Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 8: Serial Interfaces

    C13A P9715S21.HP 15n/630V Circuit of the 'Remote IN' interface at connector X2 of PKV 30-IBS The shield of the connector is connected to the earth ground of the PKV 30-IBS over a RC combination (1 MOhm, 15 nF). Signal Symbol...
  • Page 9: Remote Bus Interface 'Remote Out

    General device description 2.3.2 Remote bus interface 'Remote OUT' The PKV 30-IBS has these fieldbus interface connection to connect the bus cable to the next slave. A 9 way D-Sub female connector is used. The next picture shows the scematic of the interface. The interface is not isolated by optocouplers 2.7k...
  • Page 10: Serial Device Interface

    ü output ready to send ü input clear to send ü input RXD-N receive data inverted RS 422 Pin assignment of the serial device interface X4 Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 11: Diagnostic Interface

    The PC is connected by a three-way cable which must not be longer than 15 m. The wiring of the cable is shown below. Diagnostic cable between the protocol converter and the PC Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 12: Activation Of The Diagnostic/Configuration Mode

    If the message Connection could not be established or connection lost appears, then try to activate the dia- gnostic/configuration mode again according to the steps described above. Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 13: Status Displays - Led

    2.5 Status displays - LED On the PKV 30-IBS there are two groups of state LEDs. One group displays the state of the PKV 30-IBS device and the other group shows the state of the Inter- Bus slave. 2.5.1 Device display...
  • Page 14: Interbus Slave Display

    'Remote bus OUT' disabled interface 'Remote bus OUT' enabled green PCP data telegramms active no PCP data telegramms active Meaning of the different state LEDs of the PKV 30-IBS Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 15: Physical Dimensions

    Connector arrangement on the protocol converter Physical dimensions of the protocol converter for snap mounting to a mounting rail The overall height of the converter is approx. 80 mm. Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...
  • Page 16: Technical Data

    18V - 30V, max. 0.15 A at 24 V Operating temperature 0 to 50 degrees Celsius Safety type IP50 Dimensions (LxHxD) 105 x 105 x 80 mm Mounting rail mounting DIN EN 50022 Copyright * Hilscher Gesellschaft für Systemautomation mbH * Hotline/Support: +49 (0) 6190/9907-99 * De:P30IBS#3E...

Table of Contents