The design complies with protection class I. The HEUTE Solamat sole cleaning machines are built and tested in ac- voltage supply is 230 V AC, 50 Hz or 115 Volt AC, cordance with the latest safety regulations. The faultless functionality 50 Hz.
Declaration of Conformity Erection Electrical connection The manufacturer herewith confirms that the following machine Operation of type Solamat 90 complies with the directives listed below: Switching on and off EC Machinery Directive (2006/42/EC) Sole cleaning EC EMC Directive (2004/108/EC) Cleaning and care of the machine...
Commissioning Regular maintenance Empty the dirt drawer regularly. Erection Check belt tension: The brushes must move when the belt is The erection site must be covered. The machine must be erected moved in the direction of rotation without slippage. A round belt such that it is level and will not slip.
Page 6
Changing the roller brushes – Solamat 90 Fig. 1 Remove round belt no. 2 (size 930V) (see Fig. 5). Release the bearing rings next to both shaft flange bearings (hexagon socket screw, width across flats 2.5 mm) (see Fig. 6).
Remove round belt no. 1 (710 V) and no. 3 (700 V) (see chapter Service and repairs > Belt change - Solamat 90). Prior to removing the belts, mark these to ensure that they cannot be confused during installation. Set the motor mounting to the side.
Trouble-shooting Machine does not run only by qualified personnel Machine has no power supply Check mains power cable (see chapter Service and repairs > Belt change; in conjunction with Fig. 3) Roller and / or disc brushes do not rotate constantly Round belt tension loss Round belt without guide Round belt torn...
Technical Data Wiring diagram Solamat 90 Solamat 90/100 Dimensions: 460 x 560 x 114 mm (W x D x H) Power connection Weight: 47 kg Connection values: 230 Volt (110 Volt optional) Power: 180 Watt, 750 rpm Earth Circuit board...