10~30V DC Maximum power Current output 0.85W consumption Voltage output 1.05W Resolution 0.1m/s Transmitter circuit operating -40℃~+60℃,0%RH~80%RH temperature Measuring range 0~60m/s(default 0-30m/s) Dynamic response time ≤0.5s Precision ±0.3m/s output signal Current output 4~20mA Shandong Renke Control Technology Co., Ltd. www.renkeer.com...
Adapt to the three-wire system and the four-wire system at the same time. 3.2.3: Electrical wiring Thread color Description power supply brown Power is positive black Power negative Output blue Wind speed signal is positive green Wind speed signal negative 3.3Wiring example Shandong Renke Control Technology Co., Ltd. www.renkeer.com...
Page 6
Ø6mm are opened on the circumference of Ø47.1mm, and the bolts are used to fix it tightly. The bracket keeps the whole set of instruments at the best level to ensure the accuracy of wind speed data. The flange connection is easy to use and can withstand greater pressure. Shandong Renke Control Technology Co., Ltd. www.renkeer.com...
The range is 0~30m/s. Take 0-10V output as an example. When the output signal is 5V, calculate the current wind speed. The span of the wind speed range is 30m/s, expressed by a 10V voltage signal, 30m/s/10V=3m/s/V, that is, every 1V change in voltage corresponds to a wind Shandong Renke Control Technology Co., Ltd. www.renkeer.com...
3) The power supply voltage is wrong (24V power supply for 0-10V type). 4) The distance between the transmitter and the collector is too long, causing signal disturbance. 5) The PLC acquisition port is damaged. 6) The equipment is damaged. Shandong Renke Control Technology Co., Ltd. www.renkeer.com...
Need help?
Do you have a question about the RS-FS Series and is the answer not in the manual?
Questions and answers