Technics SL-DV250 Service Manual page 4

Dvd/video cd/cd changer
Table of Contents

Advertisement

procedure in this Technical Guide. Before replacing the traverse
unit, remove the short pin for preventingstatic electricity and
install a new unit. Connect the connector as short time as possible.
3. The flexible cable may be cut off if an excessive force is applied to
it. Use caution when handling the cable.
4. The half-fixed resistor for laser power adjustment cannot be
adjusted. Do not turn the resistor.
4.2. Grounding for electrostatic breakdown prevention
1. Human body grounding
Use the anti-static wrist strap to discharge the static electricity
from your body. (As shown in
2. Work table grounding
Put a conductive material (sheet) or steel sheet on the area where
the optical pickup is placed, and ground the sheet.
Caution:
The static electricity of your clothes will not be grounded through
the wrist strap. So, take care not to let your clothes touch the
traverse deck (optical pickup).
Fig. 1
Fig. 2
.)
Fig. 2
4