Fri-Jado MCC-60 H FS Service Manual

Modular convenience counter
Hide thumbs Also See for MCC-60 H FS:

Advertisement

Quick Links

9124729
SERVICE MANUAL
MODULAR CONVENIENCE COUNTER
MCC HOT USA
- NOTICE -
This service manual is prepared to be used by trained Service Technicians and should not be used by those not
properly qualified. If you have attended a training for this product, you may be qualified to
Perform all repair procedures, replacements and adjustments described in this service manual.
The information presented in this document is only valid for standard hot and cold modular convenience counters,
(MCC) configurations and is not intended to be all encompassing. The individual specifications may differ.
Procedures for which you do not have the necessary tools, instruments or skills should not be performed by you.
.
Technical data and specifications mentioned in this manual are subject to amendment without prior notice
Reproduction of this service manual,
Without the express written consent of Fri-Jado,
Is prohibited.
Page 1
Rev.5 Service Manual MCC Hot USA 20220500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MCC-60 H FS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fri-Jado MCC-60 H FS

  • Page 1 Procedures for which you do not have the necessary tools, instruments or skills should not be performed by you. Technical data and specifications mentioned in this manual are subject to amendment without prior notice Reproduction of this service manual, Without the express written consent of Fri-Jado, Is prohibited. Page 1...
  • Page 2 Adding FS element replacement KEEP THIS USER MANUAL FOR FUTURE USE © 2022 Fri-Jado B.V., Oud Gastel, The Netherlands. We refer to our General Terms and Conditions for Sales and Delivery that are available upon request. The manufacturer does not accept any liability for damage or injury caused by failing to adhere to these regulations or by not observing the usual caution or care in actions, operation, maintenance or repair activities, even if not explicitly described in this manual.
  • Page 3 Index 1.0 Introduction 2.0 Detailed description 3.0 Unpacking 3.1 Mounting of optional front doors. first version. 3.2 Mounting of optional front doors. Second version 4.0 Installation 4.1 Accessories 5.0 MCC Drop-in 5.1 MCC 90 Drop-in Dimensions Self Serve (For reference) 5.2 MCC Hot Drop-in Requirements Self Serve 5.3 MCC Hot Drop-in Specifications Self Serve (For reference) 5.4 MCC Drop-in Installation (Self Serve)
  • Page 4 14.0 Exploded view MCC Hot 3 Level (Self Serve) 14.1 Exploded view MCC Hot 3 Level(Self Serve) 14.01 Exploded view MCC Hot 2 Level 14.11 Exploded view MCC Hot 2 Level 14.2 Exploded view MCC Hot 3 Level (Self Serve) 14.3 Exploded view MCC Hot 3 Level(Self Serve) 14.4 Exploded view MCC Hot 3 Level (Self Serve) 14.5 Exploded view MCC Hot Structure X level (Full Serve version 1)
  • Page 5 1.0 Introduction General This manual is intended for trained technicians, performing repairs on the MDD The features and controls are being described, along with directions for the safest and most efficient way to service these counters. All pictograms, symbols and drawings in this manual apply to all available MDD models. 1.2 Identification of the unit The identification plate can be found on the outside of the machine, and contains the following data:...
  • Page 6 1.4.1 General regulations The technician, working on the unit will be fully responsible for abiding the locally prevailing safety rules and regulations. Technical activities must be performed by qualified and authorized persons only. Before working on any electrical part, or dismantling the unit by means of using a screwdriver, ALWAYS REMOVE the power plug from the main outlet.
  • Page 7 Service and technical support The electrical schematics of the unit are included at the end of this manual. In case of malfunctions which are not fixable by you, you can contact Fri-Jado. Make sure you have the following data available: •...
  • Page 8 2.0 Detailed description Technical description Self Serve Panels are made of galvanized steel plating, stainless steel and/or aluminum. Some of the visible internal and external parts have been provided with a powder coating. Glass used is tempered. Unit can be moved by means of a pallet truck. Product contact parts are made of stainless steel AISI 304 or AISI 430 and tempered glass.
  • Page 9 2.6 Technical description Full Serve Hot Humidified4 The MCC Hot FS is a multilevel serve over heated display cabinet intended for hot presentation of food products. A heating element and an array of fans are located in the base of the unit and circulate hot air throughout the cabinet, creating uniform holding conditions.
  • Page 10 Filling of the water tray can be done either by hand, or automatically. For the automatic filling system, an additional electrical box is implemented which controls the filling process. Hand filling system Automatic filling system Complete build up structure of the MCC hot Full serve first version. Second version (turnable heating compartment) Hot air flow Full Serve Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 11 3.0 Unpacking Start to unpack All packing materials used for this unit are suited for recycling. Before and during unpacking, check the state of the unit. In case of damage, photograph the damage, store the packing material, and contact the transporter as soon as possible but at the latest within fifteen working days after receiving the goods.
  • Page 12 Refer to User manual for installation procedure Mounting of optional front doors. first version. (for details, first version refer 6.0) There are 2 different heights of plastic washers to align the height of the front doors. Position the doors with the handles to the outside and with the warning sticker above the handle. Top Hinge Bottom Hinge Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 13 Put the thick or thin plastic washer (depending on leveling) on the bottom hinge pin of the door. Do this at all doors. Place the hinge pin with the nylon washer on in the bottom hole (A). Keep the door in a tilted position during this action.
  • Page 14 Adjusting the hight of the doors To adjust the doors in height after placement, Loose the mounting screws of the hinge a little. If loose, the glass can be moved slightly inside the hinge assembly Mounting of optional front doors. Second version (for details, first version refer 6.1) Rev.5 Service Manual MCC Hot USA 20220500 Page 14...
  • Page 15 4.0 Installation 4.0.0 Installation and positioning WARNING Position the unit on a flat and horizontal surface. A temporally inclined plane of maximum 5° is allowed. • Place the unit level on a sufficiently sturdy floor. • Keep the weight of the unit in mind. •...
  • Page 16 Warning Electrical shock Hazard • Grounding instructions: Only connect the appliance to an alternating current, to a grounded wall socket, with a mains voltage in accordance with the information indicated on the type plate of the appliance. • It is the consumer’s responsibility to make sure the electrical installation conforms with current national and local codes and wiring regulations.
  • Page 17 Hot FS models Water connection for automatic fill, Refer to user manual 3.6.1 Water Manually fill, Refer to user manual 3.6.2 Plateau Options On all MCC models, except the MCC Hot SS, the bottom presentation deck can be set at a variety of horizontal levels.
  • Page 18 Mounting the plinths Place the rear plinth by attaching it to both rear Adjustable legs using its two clamps. Insert the pegs of both side plinths into the slots of the rear plinth. Secure the side plinths by inserting the pegs into the slots of the front plinth, while clamping the front plinth to the front adjustable legs.
  • Page 19: Table Of Contents

    4.1 Accessories Accessoires MCC Hot Self Serve Compatibility Condiment holder 9380198 MCC 60/90/120 Merchandising rack 410 mm - Top Shelf 9384463 MCC 60/90/120 Merchandising rack 475 mm - Middle Shelf 9384473 MCC 60/90/120 Merchandising rack 550 mm - Bottom Shelf 9384475 MCC 60/90/120 Shelf divider 410 mm - Top Shelf...
  • Page 20: Price Rail Set Mcc Ss

    Price rail set MCC 120 9389813 9389813 9389813 Price rail set MCC 150 9389814 9389814 9389814 Evaporation tray 9389820 9389820 9389820 Bumper MCC 90 9380207 9380207 9380207 Bumper MCC 120 9380205 9380205 9380205 Bumper MCC 150 9380208 9380208 9380208 Castor set 9389852 9389852 9389852...
  • Page 21 5.0 MCC Drop-in Doc. nr. Rev. Registration form. MCC Drop in Unpack instruction 9124590 The MCC Drop in will be delivered, packed in a crate Start unpacking by removing top cover Page 21 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 22 Doc. nr. Rev. Registration form. MCC Drop in Unpack instruction 9124590 Remove short sides first (Left and Right), by unscrewing them. Next, remove front and back panel, they are also screwed onto the support beams under the unit. Keep the support beams for further use. Rev.5 Service Manual MCC Hot USA 20220500 Page 22...
  • Page 23 Doc. nr. Rev. Registration form. MCC Drop in Unpack instruction 9124590 Remove wrapping foil and remove corner pieces EPS foam. Unit is placed on a metal sub frame for transport purposes. Frame is kept together with metal strip at the front and the back. Keep strip in place during placing process.
  • Page 24 Doc. nr. Rev. Registration form. MCC Drop in Unpack instruction 9124590 Remove foam which holds the electrical box Remove documents and glass shelfs from unit. After placing cabinet in final position, remove tie-wraps which hold the shelf holders. Make sure the shelf holders are placed in the required sleeve, for the wanted angled or straight position of the shelfs.
  • Page 25 5.1 MCC 90 Drop-in Dimensions Self Serve (For reference) Page 25 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 26 5.2 MCC Hot Drop-in Requirements Self Serve Important remark before installation: When installing Front doors on the drop in unit, Please follow Front door installation procedure, until step in which the glass is put in. Placing the doors in a later stage, means the unit must be lifted again. Installation must comply with: •...
  • Page 27 5.3 MCC Hot Drop-in Specifications Self Serve (For reference) Page 27 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 28 5.4 MCC Drop-in Installation (Self Serve) Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 Safety instructions WARNING Self-contained units: Risk of Fire or explosion. Flammable refrigerant used. WARNING The maximum load on top of the unit may never exceed 10 kg. MINIMUM ROOM FLOOR AREA Self-contained units: Refer to the data label on the unit for the required floor area.
  • Page 29 Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 MCC Hot version: Important remark before installation: When installing Front doors on the drop in unit, Please follow Front door installation procedure (under construction), until the step in which the glass must be placed.
  • Page 30 Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 MCC Cold version: Important remark before installation: When installing Front doors on the drop in unit, Please follow Front door installation procedure 9124721, until the step in which the glass is put in. Placing the doors in a later stage, means the unit must be lifted again.
  • Page 31 Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 Step 1. Position the cabinet above the cut-out in the counter top with a forklift and support it using the wooden beams supplied with the unit Step 2. Lift the cabinet from below, using stable filler blocks and remove the wooden support beams Step 3.
  • Page 32 Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 Step 4. Remove and discard the metal transportation frame. Step 5. Install the control panel using the supplied mounting plate and screws. (up to 1 meter from the original position) Step 6.
  • Page 33 Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 Step 7. Install all remaining trim panels. Make sure ventilation openings have the correct size and the cabinet remains accessible for service and maintenance. Make sure, after build in, the cool engine is still accessible. Keep in mind the complete cool engine is extendable on self-contained units, at the back side of the unit for maintenance and service purposes.
  • Page 34 Doc. nr. Rev. Registration form. MCC Drop in installation instruction 9124589 Rev.5 Service Manual MCC Hot USA 20220500 Page 34...
  • Page 35 6.0 Installation Front door section (first version) Page 35 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 36: Mcc

    Doc. nr. Rev. Registration form. Instruction placement Front doors 9124652 6.0 Installation Front door section (first version) Step1. Remove any remaining protective coatings from the stainless steel parts provided. Step 2. Depending on variant: With standard underframe: Remove front underframe panel (two screws, one on each bottom corner).
  • Page 37 Doc. nr. Rev. Registration form. Instruction placement Front doors 9124652 6.0 Installation Front door section (first version) Step 7. Make sure to use place the white nylon rings on both side of the glass. Step 8. Bold Washer (steel) Nylon washer with collar 1 Glass Nylon washer with collar 2 Step 9.
  • Page 38: Mcc

    Doc. nr. Rev. Registration form. Instruction placement Front doors 9124652 6.0 Installation Front door section (first version) Step 13. Remove white stud. Remove top column cover (two screws) Optional Step 14. (only necessary when top column is stuck) Remove back cover(s) left and right (sliding door stopper).
  • Page 39: Mcc

    Doc. nr. Rev. Registration form. Instruction placement Front doors 9124652 6.0 Installation Front door section (first version) Step 17. Place square profiles (prepared in step 4) in previous position from child glass. Use same screws to mount. Place nylon bearing in profile (packet in bag with hinge).
  • Page 40: Mcc

    Doc. nr. Rev. Registration form. Instruction placement Front doors 9124652 6.0 Installation Front door section (first version) so they can scratch the bottom plate. Very carefully, try to close the glass door(s). They are not adjusted in height yet, so they can scratch the bottom plate. Step 22.
  • Page 41 6.1 Installation Front door section (Second version) 9124721 Service Instruction Installation front doors MCC (2nd version) The technician, working on the unit will be fully responsible for abiding the locally prevailing safety rules and regulations. Technical activities must be performed by qualifi ed and authorized persons only. Before working on any electrical part, or dismantling the unit by means of using a screwdriver or any other tool, ALWAYS REMOVE THE POWER PLUG from the main outlet.
  • Page 42: Mcc 60

    6.1 Installation Front door section (Second version) Door set 9380369 MCC 60 9380370 MCC 90 MCC 120 9380371 9380372 MCC 150 9124721 Instruction front doors MCC Page 2 Rev.5 Service Manual MCC Hot USA 20220500 Page 42...
  • Page 43 6.1 Installation Front door section (Second version) Bottom Depending on variant: With standard under frame: Remove front under frame panel (two screws, one on each bottom corner). Drop-In: Raise the unit at least 30cm from tabletop level in order to access the screws for the child- guard. Be careful to support the unit such that no components or connections underneath the base of the unit are damaged while doing so.
  • Page 44 6.1 Installation Front door section (Second version) Step 2. Remove side glass both sides: Slide the double glass pane towards the front along the top (A) and bottom (B) guiding rails. The side pane can be removed from the unit once it has slid entirety past the top guide.
  • Page 45 6.1 Installation Front door section (Second version) Step 7. Remove top column cover by removing last screw. (one each side) Step 8. Place new (longer) top column cover(s)/ window support (two screws). Mount screws in new top column cover Step 9. Replace white (or black) stud removed earlier.
  • Page 46 6.1 Installation Front door section (Second version) Step 13. Bottom Side Check placing bearing(s) in door, one in the top, one at the bottom. Make sure the fl ange of the bearing sits opposite of the glass. Flange TOP Side Step 14.
  • Page 47: Mcc 60

    9382061 9380002 MCC 120 9382063 9380098 9382124 9380137 MCC 150 Fri-Jado B.V. Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel: +31 (0) 76 50 85 400 Page 7 9124721 Instruction front doors MCC Page 47 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 48 7.0 Operation MCC Hot Hot Units The display value is not the product temperature! When switched on, the display performs a lamp test; the display and LED’s will flash for several seconds to check all function are working correctly. 7.0.1 Control Panel On/Off Switches (hot unit). Heating Lighting 7.0.2 Factory settings...
  • Page 49 7.1 Operation MCC Hot <access controller> 7.1.0 Menu Structure Quick Configuration via “cFg” menu • Press SET for three seconds to access the parameters groups. • Select “CFg” menu and press SET to enter. The first menu “r12” (main switch) is displayed. •...
  • Page 50 7.2 Operation <access controller> 7.2.0 Switching-on the unit • Switch the unit on, by means of the main switch (located top front, and/or top back) • Switch on controller for specified shelf (Multi-temp only) • Preheat the unit/shelf for at least 30 minutes. •...
  • Page 51 9124747 Service Instruction Controller replacement Due to supply issues, Fri-Jado uses diff erent kind of controllers as placed in our units from factory. Four possible controllers are used. For Service replacements we only deliver Eliwell ICPlus 902 Please fi nd below the diff erence in connections and parameters.
  • Page 52 Instruction Controller replacement Page 2 Rev.5 Service Manual MCC Hot USA 20220500 Page 52...
  • Page 53 Difference in connections between the four controllers Page 3 Instruction Controller replacement Page 53 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 54 Normal Unit Type Custom 961 next 902 plus Rev. Parameter list 9124657 MCC H SS 9124658 MCC H FS Doc. nr. Rev. Registration form. Settings – 149 °F 9124657 MCC Hot SS USA Controller: Eliwell ICPlus 902 Note: Use tool STICK 20 for inserting parameters and only change orange arced parameters manually! Note:...
  • Page 55 Doc. nr. Rev. Registration form. Settings – 203 °F 9124658 MCC HOT FS USA Controller: Eliwell ICPlus 902 Note: Use tool STICK 20 for inserting parameters and only change orange arced parameters manually! Note: When adjusting parameters manually change “dro” first if needed. User parameters: Temperature set point °F...
  • Page 56 9.0 Maintenance CLEANING AND MAINTENANCE WARNING Never use a water hose for cleaning. Water can seep into the unit through the ventilation holes of the unit. Because of hygiene aspects and optimum condition of the unit it is of up most importance to keep a daily cleaning pattern from first use onwards.
  • Page 57 Danfoss ERC 211 – 95 ° C 9124582 9.1 Parameter MCC Hot Settings (Full Serve) MCC HOT FS STICK 19 Note: Use tool for inserting parameters and only change yellow arced parameters manually! °C Temperature set point Defrost stop sensor (non=time, Air=Sair) Differential Compressor accumulated...
  • Page 58 Doc. nr. Rev. Registration form. Danfoss ERC 211 – 65 ° C 9124410 MCC Hot SS 9.2 Parameter MCC Hot Settings (Self Serve) STICK 18 Note: Use tool for inserting parameters and only change yellow arced parameters manually! °C Temperature set point Defrost stop sensor (non=time, Air=Sair) Differential...
  • Page 59 10.0 Trouble Shooting 10.0.0 Problems which can be checked by user Each user can check the following points as mentioned in the user manual: • Is the power supply OK? • Check the fuses and the earth leakage switch in the meter cup board. •...
  • Page 60 10.0 Trouble Shooting 10.0.5 Heating element testing (Full Serve units) Resistance Remove wiring (two) from the element. Connect the probe of the multimeter to each of the wires. Test the probe with a Ohmtester, values see below. Current Place ampère pliers around red wire of Element. In normal working condition, test current see below.
  • Page 61 11.0 Trouble Shooting Symptoms and causes Symptom Possible causes No power 1. Main circuit breaker open 2. Fuse Blown 3. Loose wire connection Main fuse or breaker blown 1. Wiring incorrectly 2. Short circuit heating element 3. Short circuit fan element 4.
  • Page 62 11.1 Trouble Shooting Analytical description Description of part Symptoms Possible causes Solution / Action Contactor Contactor does not Wiring Check wiring work Coil malfunction Check resistance of coil +/- 525Ω Contact burned Check the contacts Replace contactor Heating element Unit is not reaching the Wiring Check wiring (HOT unit)
  • Page 63 PTC 1000 sensor The unit is not reaching Broken Sensor Replace sensor (Hot Unit) the set temperature or does not heat up at all Loose sensor Check sensor wiring The unit becomes too Broken Sensor Replace sensor Loose sensor Check sensor wiring Water intake Not filling of Water supply closed...
  • Page 64 12.0 Replacement and Adjustments 12.1 Top glass replacement For replacement, open top glass pane entirely. Be aware of the weight of the glass. Remove the air guide (for the hot version) or the air box (for the cold version) by simply lifting them out. COLD Loosen the adjusting screws which secure the glass with a torques key...
  • Page 65 12.2. Side glass replacement The side pane glass of the units can easily be replaced. Slide the double glass pane towards the front along the top (A) and bottom (B) guiding rails. The side pane can be removed from the unit once it has slid entirety past the top guide.
  • Page 66 12.4 Sliding door Replacement (First version (magnets in rails)) (Two different versions, please select appropriate type) In order to replace the sliding doors, take following step: Remove Sliding door stopper (three screws). Left and right side. Remove rail cover, loosen mounting screws and pull cover backwards.
  • Page 67 12.4.1 Sliding door Replacement ( Second version, magnets in door (Two different versions, please select appropriate type) Recognizable: Two screws on top of rail cover. Top back side, two left and two right. In order to replace the sliding doors, take following step: Remove Sliding door stopper (three screws).
  • Page 68 12.5 Sensor Replacement (Hot Unit) Remove the brackets (two pieces, one left, one right). One Screw each. Lift bottom shelf at the front. It is turnable. Sensor is located at the back. Sensor is screwed from the outside in. Remove glass pane from lowest shelf. (see 11.10). Remove fan box.
  • Page 69 12.7 Child glass replacement Remove front panel (see 11.16). Loosen mounting screws (3x) of child glass. Screwed from underneath Place new child glass. Mount in reverse order. Mounting screws 12.8 MCC Air guide replacement Air guide replacement For replacement, open top glass pane entirely.
  • Page 70 12.9 Fan box replacement (MCC Hot) Remove air box cover (3 screws). Remove glass pane clamp. (4 or more bolts depending on unit length) Remove Glass pane (refer 11.10). Remove air box (1 connector, two screws). Replace in reverse order. Note: If replacement has to take place on a solid back unit, the back panel assembly must be removed before accessing the air box screws mentioned in step 1...
  • Page 71 12.10 Replacement of shelf glass pane Each shelf is covered with a tempered glass pane. To replace follow steps below: Remove air outlet cover by removing the screws (depending on length three or more screws) Remove glass mounting profile by removing the screws (depending on length three or more screws) Lift out glass pane, starting lifting from the back.
  • Page 72 12.11 Opening Electrical box Depending on the MCC version the electric box is placed at the back or in the front of the unit. For drop in versions the box can be placed anywhere in the build in counter. First remove the panel (back or front depending on version) Panel is fixed with two screws underneath the unit.
  • Page 73 12.12 Led light Replacement All LED Lights are mounted in the same way. Remove side glass panes. ( Refer 7.2) Remove column cover. (two screws, one on top backside and one at the bottom back side) Pull off column cover. Remove screw holding the LED housing .
  • Page 74 Loosen Element holders, depending on the version the holders are twisted at the back side, or fastened with screws. Take off the top element holders. Heating Element is now free to take out. Make a note of the placement of the wiring. Take out element.
  • Page 75 12.16 Panel Replacement Remove Plinths (refer 4.8) Front panel Remove front panel, by removing the holding screws (left and right bottom corner) Bottom view Pull panel slightly towards you and down, to remove. Replace in reverse order Back panel Remove back panel, by removing the holding screws (left and right bottom corner) Bottom view Pull panel slightly towards you and down, to remove.
  • Page 76 12.1 Hot Full serve element replacement For the MCC 60 Hot Full Serve a new heating element is implemented. Don’t place the old element type any more. Number for this kit is: 9382269s Heating element 1500W 230V (packed) Existing situation New situation Step 1.
  • Page 77 12.1 Hot Full serve element replacement Step 3. Remove bottom product plateau, both, left and right. Step 4. Remove cover deck, both left and right. Step 5. Remove GN pan, careful not to spill water. Step 6, Remove top cover from heating element box 4 bolts. Step 7.
  • Page 78 12.1 Hot Full serve element replacement Step 9. Remove rivet (4) by drilling them out, which are holding the heating element mounting brackets, both left and right. Step 10. Place new heating element holding brackets, and mount these with the bolts and nuts, as delivered. Step 11.
  • Page 79 12.1 Hot Full serve element replacement Make sure after placement, the power wire is not between the blowers and the element. Airflow should not be interrupted by the wire. Wire under airflow from blower ! Step 15. Close heating element cover (removed in step 6). Step 16.
  • Page 80 13.0 Technical Specifications MCC Hot - 2 (Full Serve) US Rev.5 Service Manual MCC Hot USA 20220500 Page 80...
  • Page 81 13.1 Technical Specifications MCC Hot - 2 (Self Serve) US Page 81 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 82 13.2 Technical Specifications MCC Hot - 3 (Full Serve) US Rev.5 Service Manual MCC Hot USA 20220500 Page 82...
  • Page 83 13.3 Technical Specifications MCC Hot - 3 (Self Serve) US Page 83 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 84 13.4 Technical Specifications MCC Hot (Self Serve) Humidified Rev.5 Service Manual MCC Hot USA 20220500 Page 84...
  • Page 85 13.5 Technical Specifications MCC Hot - 4 (Full Serve) US Page 85 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 86 13.6 Technical Specifications MCC Hot - 4 (Self Serve) Humidified Rev.5 Service Manual MCC Hot USA 20220500 Page 86...
  • Page 87 13.7 Explanation difference in levels and shelfs Level 2 Shelf 1 Level 1 Level 3 Shelf 2 Level 2 Shelf 1 Level 1 Level 4 Shelf 3 Level 3 Shelf 2 Level 2 Shelf 1 Level 1 Page 87 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 88 14.0 Exploded view MCC Hot 3 Level (Self Serve) Complete assy Rev.5 Service Manual MCC Hot USA 20220500 Page 88...
  • Page 89 14.0 Exploded view MCC Hot 3 Level (Self Serve) Number Description Article number Quantity Rear cover Shelf MCC 60 9384303 Rear cover Shelf MCC 90 9384235 Rear cover Shelf MCC 120 9384304 Fan Box Top MCC 60 9380072s See Remark Serial number Fan Box Top MCC 90 9380058s Fan Box Top MCC 120...
  • Page 90 14.1 Exploded view MCC Hot 3 Level (Self Serve) Complete assy Rev.5 Service Manual MCC Hot USA 20220500 Page 90...
  • Page 91 14.1 Exploded view MCC Hot 3 Level (Self Serve) Reflector plate MCC 60 9384086 Reflector plate MCC 90 9384226 Reflector plate MCC 120 9384184 Assy Shelf MCC 60 bottom 9380402 Assy Shelf MCC 90 bottom 9380405 Assy Shelf MCC 120 bottom 9380408 Support element bottom shelf 9384337...
  • Page 92 14.0 Exploded view MCC Hot 2 Level Rev.5 Service Manual MCC Hot USA 20220500 Page 92...
  • Page 93 14.0 Exploded view MCC Hot 2 Level Number Description Article number Quantity Soft close damper 3N 9281078 Steel roller bearing 9382100 Top Glass Square MCC 60 SS 9382165s Top Glass Square MCC 90 SS 9382164s Top Glass Square MCC 120 SS 9382166s Air guide MCC 60 9382062...
  • Page 94 14.1 Exploded view MCC Hot 2 Level 250 Middle 250 Large Rev.5 Service Manual MCC Hot USA 20220500 Page 94...
  • Page 95 14.1 Exploded view MCC Hot 2 Level Number Description Article number Quantity Soft close damper 3N 9281078 Steel roller bearing 9382100 Top Glass Square MCC 60 SS 9382165s Top Glass Square MCC 90 SS 9382164s Top Glass Square MCC 120 SS 9382166s Air guide MCC 60 9382062...
  • Page 96 14.2 Exploded view MCC Hot 3 Level (Self Serve) Complete assy Rev.5 Service Manual MCC Hot USA 20220500 Page 96...
  • Page 97 14.2 Exploded view MCC Hot 3 Level (Self Serve) Number Description Article number Quantity Rear cover Shelf MCC 60 9384303 Rear cover Shelf MCC 90 9384235 Rear cover Shelf MCC 120 9384304 Fan Box Top MCC 60 9380072s See Remark Serial number Fan Box Top MCC 90 9380058s Fan Box Top MCC 120...
  • Page 98 14.3 Exploded view MCC Hot 3 Level (Self Serve) Complete assy Rev.5 Service Manual MCC Hot USA 20220500 Page 98...
  • Page 99 14.3 Exploded view MCC Hot 3 Level (Self Serve) Reflector plate MCC 60 9384086 Reflector plate MCC 90 9384226 Reflector plate MCC 120 9384184 Assy Shelf MCC 60 bottom 9380402 Assy Shelf MCC 90 bottom 9380405 Assy Shelf MCC 120 bottom 9380408 Support element bottom shelf 9384337...
  • Page 100 14.4 Exploded view MCC Hot 3 Level (Self Serve) Rev.5 Service Manual MCC Hot USA 20220500 Page 100...
  • Page 101 14.4 Exploded view MCC Hot 3 Level (Self Serve) Number Description Article number Quantity Soft close damper 3N 9281078 Steel roller bearing 9382100 Label max. Load 10 kg 9123759 Top Glass Square MCC 60 SS 9382165s Top Glass Square MCC 90 SS 9382164s Top Glass Square MCC 120 SS 9382166s...
  • Page 102 14.5 Exploded view MCC Hot Structure X level (Full Serve version 1) Rev.5 Service Manual MCC Hot USA 20220500 Page 102...
  • Page 103 14.5 Exploded view MCC Hot Structure X level (Full Serve version 1) Number Description Article number Quantity 83 / 94 product plateau support MCC 60 9384082 product plateau support MCC 90 9384125 product plateau support MCC 120 9384290 Insulation back MCC 60 9382177 Insulation back MCC 90 9382172...
  • Page 104 14.6 Exploded view MCC Hot Structure X level (Full Serve version 2) Operator side Customer side Operator side Operator side Rev.5 Service Manual MCC Hot USA 20220500 Page 104...
  • Page 105 14.6 Exploded view MCC Hot Structure X level (Full Serve version 2) Number Description Article number Quantity 83 / 94 product plateau support MCC 60 9384082 product plateau support MCC 90 9384125 product plateau support MCC 120 9384290 106 / 107 Product plateau MCC 60 400 mm 9384082 Product plateau MCC 90...
  • Page 106 14.7 Exploded view MCC Hot 4 Level Rev.5 Service Manual MCC Hot USA 20220500 Page 106...
  • Page 107 14.7 Exploded view MCC Hot 4 Level Number Description Article number Quantity Soft close damper 3N 9281078 Steel roller bearing 9382100 Top Glass Square MCC 60 9380203s Top Glass Square MCC 90 9380200s Top Glass Square MCC 120 9380201s Air guide MCC 60 9382062 Air guide MCC 90 9382061...
  • Page 108 14.8 Exploded view MCC Hot Electrical 55 56 Rev.5 Service Manual MCC Hot USA 20220500 Page 108...
  • Page 109 14.8 Exploded view MCC Hot Electrical Number Description Article number Quantity Sensor PTC 1000 9221011 Model plate 9110810 Sticker Black Elect. Sign triangle 3500105 Thermostat ERC211 9221109 Switch 9181008 Switch dummy 30002730 Depending variation Sticker Lighting 9181071 Sticker Lower Heat 9181072 Led Armature support bracket 9384091...
  • Page 110 14.9 Exploded view MCC Hot Electrical (Humidified) 55 56 Rev.5 Service Manual MCC Hot USA 20220500 Page 110...
  • Page 111 14.9 Exploded view MCC Hot Electrical (Humidified) Number Description Article number Quantity Sensor PTC 1000 9221011 Model plate 9110810 Sticker Black Elect. sign triangle 3500105 Thermostat ERC211 9221109 Switch 9181008 Switch dummy 30002730 Depending variation Sticker Lightning 9181071 Depending variation Sticker Lower Heat 9181072 Led Armature support bracket...
  • Page 112 15.0 Electrical schematic MCC Hot (Self Serve, One phase) Schematics till production week 42 2021 Rev.5 Service Manual MCC Hot USA 20220500 Page 112...
  • Page 113 15.0.1 Electrical wiring MCC Hot (Self Serve, One phase) Page 113 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 114 15.0.2 Electrical schematic MCC Hot (Self Serve) Schematics started production week 42 2021 Rev.5 Service Manual MCC Hot USA 20220500 Page 114...
  • Page 115 15.0.3 Electrical wiring MCC Hot (Self Serve) Schematics started production week 42 2021 Page 115 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 116 15.1.0 Electrical schematic MCC Hot (Self Serve) (One phase and time relay) Rev.5 Service Manual MCC Hot USA 20220500 Page 116...
  • Page 117 15.1.1 Electrical wiring MCC Hot (Self Serve) (One phase and time relay) Page 117 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 118 15.2.1 Electrical schematic MCC Hot (Self Serve, Three phase) Rev.5 Service Manual MCC Hot USA 20220500 Page 118...
  • Page 119 15.2.2 Electrical wiring MCC Hot (Self Serve, Three phase) Page 119 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 120 15.2.3 Electrical wiring MCC Hot (Self Serve, Three phase) Schematics started production week 42 2021 Rev.5 Service Manual MCC Hot USA 20220500 Page 120...
  • Page 121 Page intentionally left blanc Page 121 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 122 15.3 Circuit Diagram MCC Hot (Full Serve first version) Rev.5 Service Manual MCC Hot USA 20220500 Page 122...
  • Page 123 15.4 Electrical wiring MCC Hot (Full Serve first version) Page 123 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 124 15.5 Circuit Diagram MCC Hot (Full Serve second version) Rev.5 Service Manual MCC Hot USA 20220500 Page 124...
  • Page 125 15.6 Circuit Diagram MCC Hot (Full Serve first second version) Page 125 Rev.5 Service Manual MCC Hot USA 20220500...
  • Page 126 Fri-Jado B.V. Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel: +31 (0) 76 50 85 400 Rev.5 Service Manual MCC Hot USA 20220500 Page 126...

This manual is also suitable for:

Mcc-90 h fsMcc-120 h fs

Table of Contents