Trouble
Motor does not run when power
switch is pressed on.
Motor does not run at full speed.
Motor will not reach full power.
Motor overheats.
Insufficient suction power.
Unit is shaking.

TROUBLESHOOTING

Probable Cause
1.Blown fuse.
2.Swith is burned out.
3.Connection wire is loose or damaged.
1.Power voltage is too low.
2.Motor is damaged.
1.Incorrect power wiring.
2.Overload.
1.Using wrong voltage.
2.Motor is damaged.
1.Inlet port blocked.
2.Filter Bag is full.
3.Outlet port blocked.
1.The unit isn't properly anchored.
2.The unit isn't leverl.
3.Worn or damaged power cord.

WIRING DIAGRAM

8
Correction
1.Replace fuse.
2.Replace the switch.
3.Tighten or replace the wire.
1.Test voltage.
2.Check and repair motor.
1.Replace incorrect power wiring.
2.Reduce load by cleaning filters
as necessary.
1.Check voltage and voltage label.
2.Check and repair the Motor.
1.Clean inlet port.
2.Empty filter bag.
3.Clean the outlet port or adjust
the direction of the outlet.
1.Mount the unit firmly.
2.Level the unit.
3.Repaire or replace power cord.