  • Page 1 Circular 7 Circular 9...
  • Page 3 Marque Modello Model Circular 7 Circular 7 - Circular 9 Modèle L'oggetto della dichiarazione di cui sopra è conforme alla pertinente normativa di armonizzazione dell'Unione: The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: L'objet de la déclaration décrit ci-dessus est conforme à...
  • Page 4 Marca / Trademark / Marque / Merk / Marke / Marca Ravelli ← 31/12/2021 Modello / Model / Modèle / Model / Modell / Modelo Circular 7 Classe di efficienza energetica / Energy Efficiency class /Classe d’Efficacité ← 31/12/2021 01/01/2022 →...
  • Page 5 FICHA DEL PRODUTO EU 2015/1186 Marca / Trademark / Marque / Merk / Marke / Marca Ravelli Modello / Model / Modèle / Model / Modell / Modelo Circular 9 Classe di efficienza energetica / Energy Efficiency class /Classe d’Efficacité Énergétique / Circular 9 Energie-efficiëntieklasse / Energieeffizienzklasse / Clase de eficiencia energética...
  • Page 7: Preface

    Incorrect installation, maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove. For further information and requirements contact your Ravelli-authorised Technical Assistance Centre. All rights reserved. No part of this instructions manual can be reproduced or transmitted through any electronic or mechanical means, including photocopies, recordings or any other storage system, for other purposes that are not exclusively use by the buyer’s staff,...
  • Page 8: Table Of Contents

    Obligations and forbidden actions ........................16 Characteristics of the fuel ............................. 17 Non-permitted fuels ..............................17 TECHNICAL CHARACTERISTICS ....................18 Technical diagram Circular 7 - Circular 9 ......................19 Main parts ................................20 Description of operation ............................20 Automatic cleaning system ............................ 21 Recharge the fuel ..............................
  • Page 9 Stove phase general layout ............................ 43 Warning Pop -Up ..............................44 Alarms (table with reference codes) ........................44 INSTALLATION QUICK GUIDE RAVELLI SMART WI - FI ............47 Connect the WiFi module cable ..........................47 App .................................... 47 Connection to the WiFi module ..........................47 Account registration ...............................
  • Page 10: Identification

    Remote control: Synthetic Declaration of Conformity (DoC) The manufacturer Aico S.p.A. declares that the Remote Control, with the Ravelli brand and model PNET00003 (Palm Touch) is in conformity with the relevant Union harmonisation legislation: 2014/53/EU (RED), and that the following harmonised standards and/ or technical specifications have been applied: ETSI EN 301 489-3, ETSI EN 301 489-1, EN 60950-1 A11+A1+A12+AC+A2, EN 62479.
  • Page 11: Label

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.11 Label Model: Circular 7 Model: Circular 9 APPARECCHIO PER IL RISCALDAMENTO DOMESTICO ALIMENTATO A PELLET DI LEGNO APPARECCHIO PER IL RISCALDAMENTO DOMESTICO ALIMENTATO A PELLET DI LEGNO RESIDENTIAL SPACE HEATING APPLIANCE FIRED BY WOOD PELLETS RESIDENTIAL SPACE HEATING APPLIANCE FIRED BY WOOD PELLETS APPAREIL DE CHAUFFAGE DOMESTIQUE À...
  • Page 12: Warranty

    Use and maintenance manual Circular Pag.12 WARRANTY Certificate of warranty Ravelli thanks you for the trust granted with the purchase of one of its products and invites the purchaser to: • read the installation, use and maintenance instructions for the product; •...
  • Page 13: General Information

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.13 GENERAL INFORMATION Supply and safe-keeping The manual is supplied in printed format. Keep this manual safe, with the appliance, so that the user can consult it easily. The manual is an integral part, for safety reasons, therefore: •...
  • Page 14: Residual Risks

    If the chimney catches fire you must call the fire brigade. ⚠ Only use original spare parts. Any tampering and/or replacements that have not been authorised by Ravelli can pose a danger to the user’s safety. ⚠ In the event of particularly adverse weather conditions, the safety systems could intervene and switch off the appliance.
  • Page 15: Description Of The Appliance

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.15 Residual Description procedure-related information risk When the appliance is running, it may reach high Risk of temperatures to the touch, especially on its external burns surfaces. Take care to avoid burns and use the specific tools if necessary.
  • Page 16: Obligations And Forbidden Actions

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.16 Obligations and forbidden actions Obligations The user must: • read this instructions manual before performing any operation on the appliance; • the appliance must not be used by children under the age of 8 or by people with reduced physical, sensorial or mental capacities or without experience or without the necessary knowledge, and always with supervision;...
  • Page 17: Characteristics Of The Fuel

    A2 and B. Maintain fuels and other flammables at a suitable distance. Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225-2:2014 standard, or certified DIN PLUS (more restrictive than the A1 class) or ONORM M 7135. Pellet may be light or dark coloured, it is normally bagged into bags that show the name of the producer, the main characteristics and classification according to standards.
  • Page 18: Technical Characteristics

    The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is used. Ravelli reserves the right to make any changes in order to improve product performance.
  • Page 19: Technical Diagram Circular 7 - Circular 9

    Use and maintenance manual Circular Pag.19 Measurements Unit of Circular 7 - measurement Circular 9 Height 1208 Width Depth Weight Technical diagram Circular 7 - Circular 9 Ø 50 (Air inlet) Ø 80 (upper smoke outlet) Ø 80 (optional smoke outlet)
  • Page 20: Main Parts

    All this can be done comfortably from the sofa using the handheld remote control. Ravelli’s patented cleaning system minimises maintenance by the user. There is no longer any need to clean the brazier before each lighting and all cleaning operations are reduced to a minimum.
  • Page 21: Automatic Cleaning System

    User training Once installation is complete, the user must always be fully trained in the functions and characteristics of the stove by the technician authorized by Ravelli to ensure optimal and safe use. The training should cover the following topics: •...
  • Page 22: Safety Devices

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.22 Safety devices The stove has been designed and equipped with safety systems to minimize user risks. It is equipped with the safety devices listed in the following table, which also intervene in case of failure of the electronic board. Element Description Pellet tank thermostat...
  • Page 23: Shipping And Installation

    Rev.1 28/10/2021 Use and maintenance manual Circular Pag.23 SHIPPING AND INSTALLATION Safety warnings for transportation and installation �� The appliance must be installed by a qualified technician, who must issue a declaration of conformity of the system to the purchaser, taking full responsibility for appliance installation and correct operation. ��...
  • Page 24: Set-Ups For The Smoke Evacuation System

    Rev.1 28/10/2021 Use and maintenance manual Circular Pag.24 ⚠ Use suitable equipment to remove the boards or wooden parts of packing. �� The end user is responsible for disposing of the packaging in accordance with the laws in force in the country of installation. ⚠...
  • Page 25: Installation

    �� Ravelli shall not be held liable if these precautions are not followed. Requirements for the installation premises The appliance installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake connected to the outdoors.
  • Page 26 Rev.1 28/10/2021 Use and maintenance manual Circular Pag.26 Installation example This type of installation (See Fig.1) requires an insulated chimney pot, even if the entire conduit is installed inside the building. Besides, the structure must be inserted into a properly ventilated skylight shaft.
  • Page 27 Rev.1 28/10/2021 Use and maintenance manual Circular Pag.27 This type of installation (See Fig.4) requires an insulated chimney pot, even if the entire smoke conduit is installed outside the Protection from rain building. In the lower part of the chimney there is a "T" type fitting installed with inspection cap.
  • Page 28: Connections

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.28 CONNECTIONS �� The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer. �� By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75 Connection with external air intake To make the connection with an external air intake, proceed as follows: step...
  • Page 29: Concentric Installation

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.29 Concentric installation Follow the regulations in force in your region for installation. ⚠ ⚠ Not provided Not provided, Ø 60 mm ⚠ Optional...
  • Page 30: Rear Smoke Outlet

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.30 ⚠ Optional Rear smoke outlet ⚠ Break the Optional kit pre-cut...
  • Page 31 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.31 ⚠ Optional kit Electrical connection The plug of the stove’s power cable must only be connected after the installation and assembly has been completed of the appliance, and must remain accessible after installation. To make the electrical connection, proceed as described below: First connect the power cable to the plug on the back of the stove and then to a wall socket.
  • Page 32: Connection Of External Probe Or Thermostat

    The testing is positive only when all operational phases have been completed without any anomaly being detected. Electric scheme Circular 7 - Circular 9 LEGEND...
  • Page 33: Controls And Use

    Radio touch remote control initialization The remote control, after a first short screen showing the Ravelli logo, will list the languages available in the menu. Select the desired language with the scroll buttons and confirm your selection with the confirmation button.
  • Page 34: Description Of The Radio Touch Remote Control

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.34 Description of the radio touch remote control The remote control looks like the following picture: The information below will familiarize you with the product and give you the best performance. Increase button “UP” (selection key) Decrease key “DOWN”...
  • Page 35: Time And Date Setting

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.35 Vers. 01 of:07.04.14 User’s manual HANDHELD TOUCH RADIO Pag.21 �� The display is subdivided into three parts: After 5 minutes of inactivity, the remote control display dims to “SLEEP” mode while maintaining the radio connection to the stove.
  • Page 36: Procedures For Use

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.36 ⚠ PROCEDURES FOR USE If the chimney catches fire you must call the fire brigade immediately. ⚠ Checks prior to start-up You have read and perfectly understood the contents of this instructions manual. Vers.
  • Page 37: Failed Ignition

    If the problem persists, it could be due to a technical problem (ignition plug, adjustments, etc ⚠ ...), so please contact a Ravelli CAT. The accumulation of unburned pellets in the brazier after a failed ignition must be removed before proceeding with a new ⚠...
  • Page 38 Pag.30 If the type of system designed requires controlling the 3-way valve (diagram 1 and 3), it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer. Stove State Stove State Combustion regulation is an operation that requires a lot of experience.
  • Page 39 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.39 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.30 Stove status Stove State Below are given the steps for accessing the relative menu starting from “Home” mode. Below are given the steps for accessing the relative menu starting from Stand-By mode. USER USER MENU...
  • Page 40: Setting

    ENABLE COMFORT COMFORT CLIMA ENABLE COMFORT Rev.1 02/11/2021 Use and maintenance manual Circular ENABLE COMFORT Pag.40 RESTART DELTA SHUTDOWN DELAY COMFORT CLIMA COMFORT CLIMA COMFORT CLIMA DELTA COMFORT CLIMA DELTA In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove. DELAY SWITCH OFF DELAY SWITCH OFF In the active phases, it indicates the operating power of the stove.
  • Page 41 ADJUST ADJUST “confirm” to “confirm” “selection” to switch access the to the function to access the function Press the key Press the key Press the key SETUP CONTRAST. “confirm” to “selection” to switch “confirm” Rev.1 02/11/2021 SETTINGS access the Use and maintenance manual Circular to the function to access the function SETUP...
  • Page 42: Ventilation Menu (Function Present Only For Ducted And Ventilated Models)

    The value can vary from -10°C to 10°C. The standard value is 0°C. Rev.1 02/11/2021 Use and maintenance manual Circular Pag.42 VENTILATION menu (function only for models in which the same is specified in the dedicate user’s manual) The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window and Ventilation menu (function present only for ducted and ventilated models) the room temperature fan installed inside them.
  • Page 43: Stove Phase General Layout

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.43 Stove phase general layout PHASE DESCRIPTION The stove is in the switch off phase and the cooling phase has FINAL CLEANING not been completed yet. The heater pre-heating phase has started and the pellets start to IGNITION fall into the grate.
  • Page 44: Warning Pop -Up

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.44 The stove has detected an anomaly; refer to the troubleshooting ANOMALY (general) chapter. By pressing the confirmation key, the problem is described. AUTOMATIC CLEANING For models with automatic cleaning system it indicates the SYSTEM ACTIVE operating state of the same.
  • Page 45 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.45 The flue is blocked. Check the flue is free and clean AL 08 DEPRESSION The vacuum meter is faulty. Check the mains voltage. FUME The fume exhaust system has a loss of AL 12 EXHAUST performance due to fan obstruction or voltage...
  • Page 46 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.46 Wifi kit WIFI MODULE MOTHERBOARD (STOVE) Wifi external power supply kit (if applicable) WIFI MODULE MOTHERBOARD (STOVE) BOARD WITH CONNECTORS FOR EXTERNAL POWER SUPPLY CONNECTION EXTERNAL POWER SUPPLY WITH MICRO USB CONNECTOR...
  • Page 47: Installation Quick Guide Ravelli Smart Wi - Fi

    (ESEMPI A e B) ATTENZIONE! ATTENZIONE! Eseguire questa operazione esclusivamente ad apparecchio freddo INSTALLATION QUICK GUIDE RAVELLI SMART WI - FI Eseguire questa operazione esclusivamente ad apparecchio freddo e con spina elettrica disinserita. Connect the WiFi module cable e con spina elettrica disinserita.
  • Page 48 CONNECTION TO THE WiFi NETWORK Rev.1 02/11/2021 Use and maintenance manual Circular Pag.48 Click in succession > Networks. The Select wifi network screen will appear. Click Scan for networks: Connection to the WiFi network select your WiFi network and enter the password if required. Close the Click in succession >...
  • Page 49: Account Registration

    Deactivate the WiFi connection on your device, open the App and Rev.1 02/11/2021 Use and maintenance manual Circular click Access to cloud. Select Register your account, enter the required Pag.49 information (the name must not contain spaces) and click Register. Account registration Deactivate the WiFi connection on your device, open the App and click Access to cloud.
  • Page 50 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.50 STEP 2 enter the product serial number and give the module a name living room stove); STEP 2 enter the product serial number and give the module a name (e.g. living room stove); STEP 3 complete with your information, click Next and then Comple STEP 3 complete with your information, click Next and then Complete registration.
  • Page 51: Maintenance

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.51 MAINTENANCE ⚠ Safety warnings for maintenance Maintenance of the stove must be performed at least once a year and should be planned in advance with the Technical ⚠ Assistance Service. In some conditions, such as turning the stove on and off or inappropriate use, the combustion products can contain small soot particles that build up in the smoke evacuation system.
  • Page 52: Extraordinary Maintenance

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.52 Glass cleaning With a cold stove, clean the glass with a cloth and glass cleaner. Note: there are stove glass cleaning products available on the market. Combustion chamber cleaning To clean the ash drawer, proceed as follows: step action Vacuum the combustion chamber every day using a bin ash vacuum, making sure that the ashes are completely cold.
  • Page 53 Use and maintenance manual Circular Pag.53 Deep combustion chamber cleaning �� This operation must be carried out by a Ravelli Assistance Centre. �� Schedule this type of cleaning with the Ravelli Assistance Centre. To clean the combustion chamber, proceed as described below: After cleaning the combustion chamber, it is advisable to proceed with the cleaning of the inspection hatches as indicated in the paragraph “Smoke duct cleaning”.
  • Page 54 Checking the seals �� This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre. When thoroughly cleaning the stove, the authorised technician must check that the gaskets of - port - hatches are intact.
  • Page 55: Failure Cases

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.55 Failure cases Problem Causes Possible remedies Alarm signal AL 05 The pellet tank is empty Load the pellets into the tank AL 06 Empty the tank to check that no objects have AL 05 The auger is blocked fallen inside that prevent the auger from...
  • Page 56 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.56 Problem Causes Possible remedies Alarm signal AL 05 The pellet tank is empty. Load the pellets into the tank AL 06 AL 05 Pellet is not loaded See previous problem AL 06 Check that the water is free to circulate in the stove and in the system, for example by checking the shut-off valves.
  • Page 57 Rev.1 02/11/2021 Use and maintenance manual Circular Pag.57 Problem Causes Possible remedies Alarm signal Remote control not associated Pair the remote control to the stove following with the stove the instructions given here Evaluate the presence of other radio devices Radio interference in the vicinity No communication...
  • Page 58: Storage And Disposal

    Rev.1 02/11/2021 Use and maintenance manual Circular Pag.58 STORAGE AND DISPOSAL Disposal Demolition and disposal of the appliance is under the exclusive liability and responsibility of the owner who must do so in accordance with the laws in force in the country of installation pertaining to safety, respect and protection of the environment. At the end of its service life, the product must not be disposed of as household waste.
  • Page 59 ITA-Informazioni per la gestione di rifiuti di apparecchiature elettriche ed elettroniche contenenti pile e accumulatori Questo simbolo che appare sul prodotto, sulle pile, sugli accumulatori oppure sulla loro confezione o sulla loro documentazione, indica che il prodotto e le pile o gli accumulatori inclusi al termine del ciclo di vita utile non devono essere raccolti, recuperati o smaltiti assieme ai rifiuti domestici.
  • Page 60 ESP-Información para la gestión de residuos de aparatos eléctricos y electrónicos con pilas y acumuladores Este símbolo que aparece en el producto, en las pilas, los acumuladores o en su embalaje o su documentación indica que el producto y las pilas o acumuladores que contiene, al final de su vida útil, no deben recogerse, recuperarse o desecharse junto con los residuos domésticos.
  • Page 64 Aico S.p.A. Headquarter Via Consorzio Agrario, 3 - 25032 Chiari (BS) - Italy Research and Development Centre Viale del commercio 12/a - 37135 Verona (VR) - Italy T. + 39 030 7402939 info@ravelligroup.it FB Ravellifuocointelligente IG ravellistufe www.ravelligroup.it Aico S.p.A. does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice.

This manual is also suitable for:

Circular 9

Table of Contents