OTHER FORMS OF TROUBLESHOOTING
Check the following points when you have problems with scanner operation.
Display panel is too dark or too bright.
Cause: The display panel brightness is not adjusted correctly.
Remedy: Adjust the display panel brightness in the User Modes.
Cannot scan with the feeder.
Cause: The ISIS/TWAIN driver [Scanning Side] setting is [Flatbed].
Remedy: Change the [Scanning Side] setting to something other than [Flatbed].
Job titles do not appear when the [Job] keys are pressed.
Cause 1: There are no jobs registered with the Job Registration Tool.
Remedy 1: Use the Job Registration Tool to register a job.
Cause 2: The computer is turned OFF or it is not connected to the scanner.
Remedy 2: Job data is stored on the computer. Make sure the computer is connected
properly and turned ON.
The Job function does not work when the [Start] key is pressed after selecting a job.
Cause 1: The computer is running an operating system that does not support the
Job function.
Remedy 1: The Job function is not supported under Windows 95 or NT. Use a computer
running another operating system when you want to use the Job function.
Cause 2: The Windows Event function is not configured to start the DR-7080C
Job Tool.
Remedy 2: On the Windows Control Panel, double-click [Scanners and Cameras] to open
DR-7080C SCSI properties. Specify [DR-7080C Job Tool] as the [Event] startup application.
Cannot scan with USB cable connections.
Cause: The SCSI terminator has not been turned ON.
Remedy: For this scanner to operate normally, the SCSI terminator needs to be turned ON
even when using USB connections. Be sure to turn ON the SCSI terminator.
A comprehensive guide to troubleshooting is included in Chapter 6 of the DR-7080C