Panasonic SA-PM3EE Service Manual page 13

Table of Contents

Advertisement

No.
Operation Procedures
1
C-mecha Abnormal Detection shall
be executed for DECK.
2
[
pressed, after loading in a
NORMAL type cassette with the
recording tab on the left side
removed.
3
[
key is pressed, after loading a
NORMAL, CrO2, METAL type
cassette with the recording tab on
the right side removed.
4
[TAPE
loading in a NORMAL, CrO2,
METAL type cassette ( cassette for
TPS checking purposes and with
both recording tabs intact ).
5
[REC] key is pressed, after loading
in a NORMAL type cassette ( with
both recording tabs intact )
6
Self-diagnostic mode is stopped by
pressing the [
7
To clear all the abnormalities in the
memory, press the [
more than 5 Sec while the self-
diagnostic mode is stopped.
8
To cancel the self-diagnostic mode
press the
- If RAM check error occurs during microcomputer reset, COLDSTART
shall be executed and all the error memory shall be cleared during RAM
initialization.
8.1.2. EEPROM Checksum (ROM correction)
Purpose : To check for micro-processor firmware version & EEPROM check (ROM correction).
Below is the procedures for this mode.
Step 1: Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into
this mode.
Step 2: Check for firmware version & EEPROM checksum.
] key is
]
] Key is pressed, after
] Key.
] Key for
Key.
Micon operation & processing
Check that all DECK mechanism leaf SW is in OFF state.
FF shall be executed for 2 sec, after which STOP. /
Check the following. / { F.REC INH SW } is OFF / { HALF
SW } is ON / Reel pulse toggles between H & L.
REW shall be executed for 2 sec, after which STOP. /
Check the following. / { F.REC INH SW } is ON / { HALF
SW } is ON / Reel pulse toggles between H & L.
TPS operation is executed. Check the following. / { F.REC
INH SW } is ON / { HALF SW } is ON / TPS signal changes.
/ After checking TPS, it shall STOP. / If TPS checking is
completed at TAPE END, it is considered as TPS
abnormal.
REC operation shall not be executed. / Check the
following. / { F.REC INH SW } is ON / { HALF SW } is ON
LCD shall display the abnormality item code, when the
STOP key is pressed, it shall display the abnormality item
code in the following sequence. / [ TEST H 0 1] [ TEST H 0
2] [ TEST H 0 3]
At this time, all the abnormalities item in the memory is
cleared and is displayed on the LCD.[ C L E A R ] display
for 1 Sec. then,[ TEST ] is displayed.
POWER is OFF.At the next POWER ON, normal operation
shall be executed.