Adjustment Standard (Handset); Adjustment Standard (Charger Unit) - Panasonic KX-TCA155E Service Manual

Dect portable station
Table of Contents

Advertisement

13.2. Adjustment Standard (Handset)

When connecting the Simulator Equipments for checking, please refer to below.
13.3. Adjustment (Charger Unit)
Items
(A) Charging Check
Note:
After the measuring, sock up the solder of TP.

13.4. Adjustment Standard (Charger Unit)

When connecting the Simulator Equipments for checking, please refer to below.
13.4.1. Flow Solder Side View
14. RF SPECIFICATION
14.1. Handset
Item
TX Power
Modulation
Frequency Offset
Frequency Drift
RX Sensitivity
Timing Accuracy
RSSI Level
Power RAMP
** : Refer to
Adjustment (Handset)
Adjustment
Point
1. Connect Charge Contact 12
-
2. Measure and confirm voltage across the regigster is 2.7V ± 0.2V.
Value
20 dBm ~ 25 dBm
360 kHz/div ~ 380 kHz/
div
-45 kHz ~ +45 kHz
< ± 30 kHz / ms
< 1000 ppm
< ± 0.5 ppm
0x11 hex ± 8 hex (at -
81dBm)
0x1E hex ± 8 hex (at -
63dBm)
Power RAMP is
matching
()
Procedure
/2W register between charge+ and charge-.
Refer to -. **
Adjustment (Handset)
Adjustment (Handset)
Adjustment (Handset)
Adjustment (Handset)
Adjustment (Handset)
Adjustment (Handset)
Adjustment (Handset)