Philips MAGNAVOX 20MC4304 Service Manual page 104

Color tv with built-in vcr/dvd player
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note:
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White Win-
dow, Red Color, Dot Pattern, Gray Scale, Mono-
scope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (VFMS0001H6), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
8. Color Analyzer
How to make service remote control
unit:
1. Prepare remote control unit (ID No. NE206UD, Part
No. 4835 218 37345). Remove 4 screws from the
back lid (Fig. 1-1).
SCREW
Remote control unit (Bottom)
2. Cut off pin 10 of the remote control microprocessor
and short circuit pins 10 and 17 of the microproces-
sor with a jumper wire
How to Set up the Service mode:
Service mode:
1. Use the service remote control unit.
2. Turn the power on. (Use main power on the TV
unit.)
3. To enter the TV mode, press "CH o / p" button on
the TV unit.
4. Press "DISC MENU" button on the service remote
control unit. Version of micro computer will display
on the CRT. (Ex: 057-001)
X-Ray Protection Test
X-Ray protection test should be done when replacing
any parts of this chassis.
1. Short both ends of R592 (on Sub CBA).
2. Confirm that the main power turns off.
3. If the main power does not turn off, then replace
the following parts (D591, Q591, R592, R593,
R594 and IC201).
4. Perform steps 1 to 3 again.
1. DC 114V (+B) Adjustment
Purpose: To obtain correct operation.
Symptom of Misadjustment: The picture is dark and
unit does not operate correctly.
Test point
D613 Cathode (+B),
HEAT SINK (GND)
Note:
D613 Cathode (+B), HEAT SINK, VR601 --- Main CBA
1. Connect the unit to AC Power Outlet.
2. Connect DC Volt Meter to D613 Cathode (+B) and
HEAT SINK (GND).
3. Adjust VR601 so that the voltage of D613 Cathode
(+B) becomes +114±1.0V DC.
Fig. 1-1
1-9-1
Adj. Point
VR601
Tape
M. EQ.
---
DC Voltmeter
Mode
Input
---
-----
Spec.
+114±1.0V DC
T1006EA

Advertisement

Table of Contents
loading

Table of Contents