9.3. Adjustment X101
IN case of SS system, Carrier signal frequency directly can not be measured by Frequency
counter, because sending signal is spread by PN code.
So, the confirmation and adjustment is made under the Continuous Send mode of TEST MODE.
Adjust the TX carrier (CW) frequency on the RF unit.
Equipment: Frequency counter
TP for adjustment: TP_ANT
Adjustment point: VC101 (RF unit)
Adjustment range: 906.000 ± 0.002 MHz (1ch)

9.4. Base Unit Reference Drawing

Component View
Flow Solder Side View