Summary of Contents for Global Water GL500-2-1

  • Page 1 Global Water 800-876-1172 • globalw.com GL500-2-1 Data Logger Covers GL500U-2-1 and GL500S-2-1 Data Loggers Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int’l: (916) 638-3429, F: (916) 638-3270 globalw@globalw.com 11/30/09 01-460 - 1 -...
  • Page 2: Table Of Contents

    Global Water 800-876-1172 • globalw.com Congratulations on your purchase of a Global Water GL500-2-1 Data Logger. This instrument has been quality tested and approved for providing accurate and reliable measurements. We are confident that you will find the logger to be a valuable asset to your applications. Should you require assistance, our technical staff will be happy to help.
  • Page 3: Checklist

    Global Water’s obligations under this warranty are limited to, at Global Water’s option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall Global Water’s liability exceed the products original purchase price.
  • Page 4: Specification

    Global Water 800-876-1172 • globalw.com Specification: Power Supply: Two 9VDC alkaline batteries standard 5 VDC Min. to 24.0 VDC Absolute Maximum Standby Current: 65uA Typical Logging Current: 5mA Typical + sensor current Operating Temperature Industrial, -40ºC to +85ºC (Batteries may not apply)
  • Page 5: System Requirements

    Note that the software provided with the data loggers is for running on desktop and laptop computers only. Software for many popular Handheld PDA devices is available from Global Water. Special cables may be required. Software Installation: Global Logger Installation: This software is for use on Windows based desktop and laptop computers only.
  • Page 6 Global Water 800-876-1172 • globalw.com GL500U Only The following menus apply to the Windows XP operating system. 1) Do not let Windows search for software. Click “No, not at this time” when asked if Windows Update can search for software.
  • Page 7 Global Water 800-876-1172 • globalw.com GL500U Only 4) The Hardware Wizard searches for the driver. If Windows advises that the software is not certified, click: “Continue Anyway”. This only means that Microsoft has not licensed the software. Second party software is allowed and no harm will come to your computer.
  • Page 8: Direct Connection

    However; this communication software also supports loggers which may be programmed in a Fixed Baud Rate Mode. This is useful in telemetry applications, particularly when using Global Water data loggers with our Global Access radio modem software. The upcoming discussion assumes that the logger is programmed in auto detect mode.
  • Page 9: Modem Connection

    Global Water 800-876-1172 • globalw.com To make a direct connection to the logger, click the “Direct” option and from the “Port” menu, select the port you wish to use. For USB access (GL500U) select the USB serial port at the COM port the driver was assigned, which is automatically shown in the list as “Global Logger USB Device”.
  • Page 10 Global Water 800-876-1172 • globalw.com GL500S Only settings must be made to the remote modem and an initialization file may be required to properly configure the host modem. Two baud rates are supported 9600 and 19200. Should you experience difficulty establishing a reliable connection at 19200, try the slower connection speed.
  • Page 11 Global Water. The remote modem is configured by setting DIP switches. They should be set to auto-answer on, DTR Normal, carrier detect normal and smart mode. Global Water can provide external modems and interface cables at an additional cost if requested.
  • Page 12: Main Screen

    Global Water 800-876-1172 • globalw.com Main Screen: The main screen is where the status and option menus are accessed. The data logger will continue to log at normal intervals while connected to the Global Logger software. While connected, the logger will draw an addition current from the power supply of 5-10mA so it is advised that, if you plan to not access the logger for extended periods of time, you disconnect to increase battery life.
  • Page 13 Global Water 800-876-1172 • globalw.com Tool Bar: The tool bar at the top of the screen has 3 options; File, Action and Help. In this screen, the File option is used to exit the program only. Action allows a menu driven interface to the various functions and displays the hot-keys, which can be used for fast access.
  • Page 14 Global Water 800-876-1172 • globalw.com Records: This field indicates the number of data recordings in memory. Logging State: This shows whether the data logger is currently logging or waiting to be started or stopped by the alarm timers. These features are described in detail later.
  • Page 15 Successive numerical readings taken by using Sample Continuously or Get Sample are shown in a list below the bar, up to 5. Pulse channel: The GL500-2-1 Data Logger has one pulse channel with a maximum count of 65,535. At the time of the logger’s normal sampling interval, the counts are stored in memory along with the other sensor data and time stamp, and then the counters are set to zero to start the counting sequence over again.
  • Page 16: On-Line Help Files

    Global Water 800-876-1172 • globalw.com On-Line Help Files: Clicking on Help displays the on-line help files which contain all of the information contained in this manual. There are 3 ways to access the information. The first tab is Contents which accesses the table of contents for the manual. Clicking on any of...
  • Page 17: Get History

    Global Water 800-876-1172 • globalw.com Get History: Clicking the Get History button begins the downloading of the historical data into an information screen. This screen allows the viewing of the recorded data and also provides a path to export the data to an Excel compatible file (.CSV file). Note that the logger continues to log as data is downloaded.
  • Page 18: Setup Menus

    Global Water 800-876-1172 • globalw.com Save to File: Clicking this button allows the data to be exported to an Excel compatible .CSV file. Specify the path and the file name and click the Save button Options: This opens a menu which...
  • Page 19: General Setup

    A warning message will appear before this action is taken. Help: The Help menu provides access to the on-line help files and Global Water contact information as described previously. XIII. General Setup: In the General Setup menu, the logger name, sensor warm-up time, logging mode, logging interval and alarm times are entered.
  • Page 20 Only change this to a fixed baud rate if planning to use this logger in a telemetry application, such as using Global Water’s Global Access radio modem software. Once programmed in a fixed rate mode, you must set the baud rate in the opening connection menu of the Global Logger II software to this speed, or the logger will not communicate.
  • Page 21 Global Water 800-876-1172 • globalw.com Logarithmic Timing: Typically used in groundwater pump studies, this mode speeds up the sample rate over time. Click the “Logarithmic” option to select this mode. This a logarithmic approximation that steps up the sample rate: a.
  • Page 22: Analog Setup

    Global Water 800-876-1172 • globalw.com Alarm Times: Check the box associated with each alarm to enable that feature and enter the desired start or stop time. The logger will start at the next occurrence of the Alarm 1 time and stop at the next occurrence of the Alarm 2 time after the Alarm 1 timer has expired.
  • Page 23 Global Water 800-876-1172 • globalw.com The calibration of channel one to a water level sensor is discussed in the following example where it is not possible to calibrate the sensor over its full range. The water level sensor shown is designed to measure over the range of 0-15 feet but a water column of 15 feet may not be available.
  • Page 24 Global Water 800-876-1172 • globalw.com Disp High: This field sets the upper limit of the bar graph displayed in the main screen and provides a way of scaling the graph beyond the upper limit used to calibrate the logger. In this example, the upper calibration point was a water level of 8 feet but the maximum range of the sensor is 16 feet.
  • Page 25: Digital Setup

    Global Water 800-876-1172 • globalw.com Click on the Low EU field and enter the low engineering unit that will be used to calibrate the logger, not necessarily the lowest reading the sensor can output. In this example, the value is zero feet, which is the lowest calibration point and water level.
  • Page 26 Global Water 800-876-1172 • globalw.com Enable: Checking the Enable box allows the display of the data for that channel in the historical record. The pulse channels are always being monitored and the counts between sampling intervals stored whether they are enabled or not.
  • Page 27: Programming

    Global Water 800-876-1172 • globalw.com XVI. Programming Program Settings: The Program Settings button at the bottom of the setup menus will cause all the setup and calibration information to be programmed into the data logger. A warning will appear requiring the use to confirm the action.
  • Page 28: Input Connections

    Global Water 800-876-1172 • globalw.com XVII. Input Connections The digital input uses a standard RCA jack on the bottom of the case and 2 strain reliefs are provided for feeding sensor cables into the case where the analog input connector is.
  • Page 29: Modem Cable Diagram

    800-876-1172 • globalw.com XVIII. Modem Cable Diagram (GL500S Only): The following wiring diagram is used to make a cable to connect the GL500S Data Logger to an external modem. A Pre-wired cable is available from Global Water. - 29 -...
  • Page 30: Maintenance

    Check the communication cable. c. If the connection is to the GL500S using the serial cable provided by Global Water, verify that the correct COM port is selected in the connection menu of the Global Logger software. d. If the connection is to the GL500U through the USB port, use the...
  • Page 31: Customer Support

    Global Water 800-876-1172 • globalw.com XXI. Customer Support: Call Global Water for tech support: 800-876-1172 or 916-638-3429 (many problems can be solved over the phone). Fax: 916-638-3270 or Email: globalw@globalw.com. When calling for tech support, have the following information ready: 1.
  • Page 32: Ce Certification

    Batteries Directive: 2006/66/EC; Requirements regarding the proper handling and disposal of batteries and accumulators. Global Water hereby certifies that the product stated above conforms to all directives and standards required for it to bear the CE mark. Dale Daniel Engineering Manager Global Water Instrumentation, Inc.