Summary of Contents for Global Water GL500-7-2

  • Page 1 Global Water 800-876-1172 • globalw.com GL500-7-2 Data Logger Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int’l: (916) 638-3429, F: (916) 638-3270 globalw@globalw.com 11/30/09 01-401 - 1 -...
  • Page 2: Table Of Contents

    Global Water 800-876-1172 • globalw.com Congratulations on your purchase of a Global Water GL500 Data Logger. This instrument has been quality tested and approved for providing accurate and reliable measurements. We are confident that you will find the logger to be a valuable asset to your applications. Should you require assistance, our technical staff will be happy to help.
  • Page 3: Checklist

    Global Water’s obligations under this warranty are limited to, at Global Water’s option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall Global Water’s liability exceed the products original purchase price.
  • Page 4: Gl500 Specification

    Global Water 800-876-1172 • globalw.com GL500 Specification: Power Supply: Voltage: 4.2 VDC Min. to 24.0 VDC Absolute Maximum Standby Current: 70uA Typical Logging Current: 5mA Typical + sensor current Operating Temperature Industrial, -40ºC to +85ºC (Battery may not apply) Analog Sensor Inputs:...
  • Page 5: System Requirements

    Note that the software provided with the GL500 data logger is for running on desktop and laptop computers only. Software for many popular Handheld PDA devices is available from Global Water. Special cables may be required. Software Installation: Global Logger Installation: This software is for use on Windows based desktop and laptop computers only.
  • Page 6 Global Water 800-876-1172 • globalw.com The following menus apply to the Windows XP operating system. 1) Do not let Windows search for software. Click “No, not at this time” when asked if Windows Update can search for software. Click Next.
  • Page 7 Global Water 800-876-1172 • globalw.com 4) The Hardware Wizard searches for the driver. If Windows advises that the software is not certified, click: “Continue Anyway”. This only means that Microsoft has not licensed the software. Second party software is allowed and no harm will come to your computer.
  • Page 8: Direct Connection

    However; this communication software also supports loggers which may be programmed in a Fixed Baud Rate Mode. This is useful in telemetry applications, particularly when using Global Water data loggers with our Global Access radio modem software. The upcoming discussion assumes that the logger is programmed in auto detect mode.
  • Page 9 Global Water 800-876-1172 • globalw.com There are 3 ways to connect to the GL500 data Logger, direct connection through the RS-232 serial port or USB port and dial out through an installed modem. To make a direct connection to the logger, click the “Direct” option and from the “Port”...
  • Page 10: Modem Connection

    Global Water 800-876-1172 • globalw.com VIII. Modem Connection: Access to the GL500 can be made through dial-out to a remote modem by clicking the “Modem” option. The connection from modem to logger requires an RS-232 serial modem, USB modems are not supported as an interface to the logger. Also, some switch settings must be made to the remote modem and an initialization string may be required to properly configure the host modem.
  • Page 11 When connecting the GL500 Data Logger to an external modem, a special cable is required. Wiring diagrams are provided at the end of this manual and pre-wired cables are available from Global Water. The remote modem is configured by setting DIP switches. They should be set to auto-answer on, DTR Normal, carrier detect normal and smart mode.
  • Page 12: Main Screen

    Global Water 800-876-1172 • globalw.com Main Screen: The main screen is where the status and option menus are accessed. The GL500 data logger will continue to log at normal intervals while connected to the Global Logger software. While connected, the logger will draw an addition current from the...
  • Page 13 Global Water 800-876-1172 • globalw.com Tool Bar: The tool bar at the top of the screen has 3 options; File, Action and Help. In this screen, the File option is used to exit the program only. Action allows a menu driven interface to the various functions and displays the hot-keys, which can be used for fast access.
  • Page 14 Global Water 800-876-1172 • globalw.com Records: This field indicates the number of data recordings in memory. Logging State: This shows whether the GL500 is currently logging waiting to be started or stopped by the alarm timers. These features are described in detail later.
  • Page 15 Global Water 800-876-1172 • globalw.com Bar Graphs: The bar graphs show a visual representation of the most recent data reading taken by using the Sample Continuously or Get Sample functions. The upper and lower limits of the display are defined by the user as discussed in detail later.
  • Page 16: On-Line Help Files

    Global Water 800-876-1172 • globalw.com On-Line Help Files: Clicking on Help displays the on-line help files which contain all of the information contained in this manual. There are 3 ways to access the information. The first tab is Contents which accesses the table of contents for the manual. Clicking on any of...
  • Page 17: Get History

    Global Water 800-876-1172 • globalw.com Get History: Clicking the Get History button begins the downloading of the historical data into an information screen. This screen allows the viewing of the recorded data and also provides a path to export the data to an Excel compatible file. Note that the logger continues to log as data is downloaded.
  • Page 18: Setup Menus

    Global Water 800-876-1172 • globalw.com Save to File: Clicking this button allows the data to be exported to an Excel compatible .CSV file. Specify the path and the file name and click the Save button Options: This opens a menu which...
  • Page 19: General Setup

    A warning message will appear before this action is taken. Help: The Help menu provides access to the on-line help files and Global Water contact information as described previously. XIII.
  • Page 20 Only change this to a fixed baud rate if planning to use this logger in a telemetry application, such as using Global Water’s Global Access radio modem software. Once programmed in a fixed rate mode, you must set the baud rate in the opening connection menu of the Global Logger II software to this speed, or the logger will not communicate.
  • Page 21 Global Water 800-876-1172 • globalw.com Logarithmic Timing: Typically used in groundwater pump studies, this mode speeds up the sample rate over time. Click the “Logarithmic” option to select this mode. This a logarithmic approximation that steps up the sample rate: a.
  • Page 22: Analog Setup

    Global Water 800-876-1172 • globalw.com once per hour as well as the time that the sample-on-demand was triggered. This feature is used to record the time that special events occurred such as when water sampler was triggered, a door was opened, etc.
  • Page 23 Global Water 800-876-1172 • globalw.com The calibration of channel one to a pH sensor is discussed in the following example where it is not practical to calibrate a sensor over its full range. The pH sensor is measures over the range of zero to 14 but is generally calibrated over a lesser range such as 4 and 10 even when it is desirable to measure beyond these limits.
  • Page 24 Global Water 800-876-1172 • globalw.com calibrate the logger. In this example, the upper calibration point was a pH of 10 but the bar graph will end at 14. Disp Low: This field sets the lower limit of the bar graph displayed in the main screen and provides a way of scaling the graph beyond the lower limit used to calibrate the logger.
  • Page 25: Digital Setup

    Global Water 800-876-1172 • globalw.com Click on the Low EU field and enter the low engineering unit that will be used to calibrate the sensor, not the lowest reading the sensor can output. In the example of pH, enter 4 which is the lowest calibration solution to be used.
  • Page 26 Global Water 800-876-1172 • globalw.com Enable: Checking the Enable box allows the display of the data for that channel in the historical record. The pulse channels are always being monitored and the counts between sampling intervals stored whether they are enabled or not.
  • Page 27: Programming

    Global Water 800-876-1172 • globalw.com XVI. Programming Program Settings: The Program Settings button at the bottom of the setup menus will cause all the setup and calibration information to be programmed into the data logger. A warning will appear requiring the use to confirm the action.
  • Page 28: Connections

    Global Water 800-876-1172 • globalw.com XVII. Connections: Left Hand Connector: Pulse channel 2 +, connected to VBAT P2 IN Pulse channel 2 pulse input Pulse channel 1 +, connected to VBAT P1 IN Pulse channel 2 pulse input SMP+ Sample-On-Demand +, VBAT...
  • Page 29: Modem Cable Diagrams

    Global Water 800-876-1172 • globalw.com XVIII. Modem Cable Diagrams: Use the following wiring diagrams to make a cable to connect the GL500 Data Logger to an external modem. Pre-wired cables are available from Global Water. - 29 -...
  • Page 30: Maintenance

    XIX. Maintenance: a. Except for an optional battery pack, there are no user-serviceable parts inside the Data Logger. b. Global Water recommends checking the battery on a regular basis, the period depending on the type of battery used. Troubleshooting: Issue: Logger is reading incorrectly.
  • Page 31: Customer Support

    Global Water 800-876-1172 • globalw.com XXI. Customer Support: Call Global Water for tech support: 800-876-1172 or 916-638-3429 (many problems can be solved over the phone). Fax: 916-638-3270 or Email: globalw@globalw.com. When calling for tech support, have the following information ready: 1.
  • Page 32: Ce Certification

    Batteries Directive: 2006/66/EC; Requirements regarding the proper handling and disposal of batteries and accumulators. Global Water hereby certifies that the product stated above conforms to all directives and standards required for it to bear the CE mark. Dale Daniel Engineering Manager Global Water Instrumentation, Inc.