• Constant current constant voltage charging (CCCV) is recommended for LFP batteries. Refer to diagram
below for illustration:
4.4. Discharging
• Do not exceed the maximum discharge current as specified in the data sheet.
• Avoid discharging the LFP battery at its maximum current (1C) several times in succession, as this may
cause the BMS to cut out.
• The maximum continuous load should not exceed 1100W. A maximum 1000W inverter can be connected to
avoid damaging the battery including the BMS and the cells.
DISCHARGE CHARACTERISTICS
14.0
13.5
13.0
12.5
12.0
11.5
11.0
10.5
10.0
0
20
40
LITHIUM PRO
LITHIUM
60
80
100
Capacity (%)
ADVANCED LiFePO TECHNOLOGY
0.1C
0.2C
0.5C
1C
120
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
PRO
15