1. This fountain is to be mounted on a smooth, flat, finished wall surface, with adequate support structure.
2. Establish rim height fountain is to be mounted at.
3. Refer to rough-in for plumbing.
4. Locate and install trap (not included).
5. Install shut-off valve (not included) on building water supply.
6. Secure fountain using 1/4" (6mm) lag screws or bolts (not included).
CAUTION: This fountain is rated for inlet water pressure of 20-90 psi. Should the inlet water supply
exceed 90 psi, a pressure reducing regulator should be used.
7. Connect fountain to building supply line by running a water line between the shut-off valve and fountain.
8. Turn on water supply and check all connections for leaks.
9. Adjust bubbler stream height. (See instructions below)
PROJECTOR: If mineral deposits build up in the orifice, they can be
removed by using a round file or small diameter wire.
CAUTION: Care must be taken not to damage orifice assembly.
STREAM REGULATOR: Stream height is factory set at 45-50 psi.
If supply pressure varies greatly from this, remove the
cap from the bubbler assembly/valve regulator and
adjust the screw on the regulator. Clockwise adjustment
will raise stream height and counterclockwise will lower
stream height. A stream height of 1-1/2" (38mm) is
recommended. (See Fig. 1)
All manuals and user guides at all-guides.com
4540-FTN
MODEL 4540 FOUNTAIN
INSTALLATION INSTRUCTIONS
TROUBLE SHOOTING & MAINTENANCE
FIG. 1

Advertisement

loading

Summary of Contents for Halsey Taylor 4540

  • Page 1 All manuals and user guides at all-guides.com 4540-FTN Halsey Taylor Owners Manual MODEL 4540 FOUNTAIN INSTALLATION INSTRUCTIONS 1. This fountain is to be mounted on a smooth, flat, finished wall surface, with adequate support structure. 2. Establish rim height fountain is to be mounted at.
  • Page 2 All manuals and user guides at all-guides.com 4540-FTN PARTS LIST 115V FIG. 2 13, 16 SEE FIG. 2 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.3500 PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620...

This manual is also suitable for:

4540-ftn