PHILIPS 4000 and 3000
Action by user
Switch on green Led under the Hot Water
button
ERROR: Led Hot-Water remains off, check
the interface board and flat cable (JP21)
Finish condition: NO BU, NO drag drawer,
door open and No Water sensor
Level 2 (Input)
Start condition: NO BU, NO drag drawer, door open and
No Water sensor
Action by user
Switch off Red Leds NoWater
ERROR: Led NoWater remains on, check the capacitive
sensor (fixing) and the wiring (JP23)
Action by user
Switch off Red Leds GenAlarm
ERROR: Led GenAlarm remains on, check the BU presen-
ce Microswitch and the wiring (JP16).
Action by user
Switch off Red Led Dreg drawer full
ERROR: Led Dreg drawer full remains on, check the Mi-
croswitch for the door and the wiring (JP14).
NOTE: without the Dreg drawer correctly inserted the in-
dication cannot change!
Finish condition: With BU, Drag Drawer, door closed and
Tank
Press Hot Water Button
NoBeans
Press BUTTON Stand-By to move to the next screen
Insert a full Water Tank
Insert the Brew Unit
Insert Dreg drawer and close the service door
LED INDICATION
Led Steam Button
OFF
OFF
LED INDICATION
Led
Led
NoWater
GenAlarm
OFF
OFF
Led
NoBeans
OFF
Led
NoBeans
NA
NA
Led
NoBeans
NA
NA
Led
NoBeans
NA
NA
Led
NoBeans
OFF
05 SERVICE MODE
Led Hot-Water Button
Led
Led Dreg
drawer full
Descale
OFF
OFF
LED INDICATION
Led
Led
NoWater
GenAlarm
ON
ON
LED INDICATION
Led
Led
NoWater
GenAlarm
OFF
NA
ON
NA
LED INDICATION
Led
Led
NoWater
GenAlarm
NA
OFF
ON
NA
LED INDICATION
Led
Led
NoWater
GenAlarm
NA
NA
NA
NA
LED INDICATION
Led
Led
NoWater
GenAlarm
OFF
OFF
ON
OFF
Led
Led
Rinsing
OFF
OFF
Led Dreg
drawer full
ON
Led Dreg
drawer full
NA
NA
Led Dreg
drawer full
NA
NA
Led Dreg
drawer full
OFF
ON
Led Dreg
drawer full
OFF
13/18