Power Cord - LG LP093CD3B Svc Manual

Packaged terminal air conditioner
Table of Contents

Advertisement

2.3.5 POWER CORD

1. Remove the control box. (Refer to section 2.1.2)
2. Disconnect the grounding screw from the control
box.
3. Disconnect 2 receptacles.
4. Remove a screw which fastens the clip cord.
5. Separate the power cord from the control box.
(See Figure 17)
6. Re-install the component by referring to the
removal procedure, above.
(Use only one ground-marked hole
connection.)
7. If the supply cord of this appliance is damaged, it
must be replaced by an exact replacement part.
(The special cord means the cord which has the
same specification marked on the supply cord
fitted to the unit.)
2.3.6 P.C.B.
1. Remove the escutcheon.
2. Remove the two knobs.
3. Remove the 2 screws which fasten P.C.B. cover.
4. Disconnect all the leads which connected to the
P.C.B.
5. Remove the two screws which fasten the P.C.B.
board.
6. Re-install the components by referring to the
removal procedure, above.
WARNING
After servicing control box ,make sure that AC and DC
wires are separated and tied up properly.
The wires should also be pressed a little downwards to
prevent touching it to the display pcb.
Copyright ©2012 LG Electronics. Inc. All right reserved.
Only for training and service purposes
for ground
Figure 17
Figure 18
- 17 -
LGE Internal Use Only