[ 078-2. Running Status Request ] - NEC UM351WGi-B Command Reference Manual

Table of Contents

Advertisement

3.34

[ 078-2. RUNNING STATUS REQUEST ]

Gets the information about the operation status of the projector.
Command
00h 85h 00h 00h 01h 01h 87h
Response
When the command succeeds
20h 85h <ID1> <ID2> 10h <DATA01> - <DATA16> <CKS>
Data part
Item
DATA01 - 02
DATA03
DATA04
DATA05
DATA06
DATA07 - 16
When the command fails
A0h 85h <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>
©NEC Display Solutions, Ltd. 2014-2020
Reserved for the system
Power status
00h
Standby
01h
Power on
Cooling process
00h
Not executed
01h
During execution
Power On/Off process
00h
Not executed
01h
During execution
Operation status
00h
Standby (Sleep)
04h
Power on
05h
Cooling
06h
Standby (error)
Reserved for the system
Description
FFh
FFh
FFh
0Fh
10h
FFh
61
Not supported
Not supported
Not supported
Standby (Power saving)
Network standby
Not supported