ProCurve Switch 3500yl-24G-PWR
ProCurve Switch yl 10-GbE 2P CX4 + 2P X2 Module
(J8694A)
10-GbE module with two fixed CX4 ports and two X2 slots
for ProCurve Switch 3500yl series and ProCurve Switch
6200yl-24G-mGBIC
zl Modules
ProCurve Switch 5400zl 24p Mini-GBIC Module
(J8706A)
24-port mini-GBIC module for 5400 series switches
Ports
2 open transceiver slots
2 10-Gigabit Ethernet ports (IEEE 802.3ak
Type 10Gbase-CX4)
Duplex: full
Physical characteristics
Dimensions: 7.76 (d) x 7.52 (w) x 14.29 (h)
in. (19.7 x 19.1 x 36.3 cm)
Weight: 1.54 lb. (.7 kg)
Environment
Operating temperature: 32°F to 131°F (0°C
to 55°C)
Operating relative humidity: 15% to 95%,
non-condensing
Non-operating/Storage temperature: -40°F
to 158°F (-40°C to 70°C)
Non-operating/Storage relative humidity:
15% to 90%, non-condensing
Ports
24 open mini-GBIC slots
Physical characteristics
Dimensions: 10.3 (d) x 8.13 (w) x 1.75 (h)
in. (26.16 x 20.65 x 4.45 cm)
Weight: 2.01 lb. (0.91 kg)
Environment
Operating temperature: 32°F to 104°F (0°C
to 40°C)
Mini-GBICs supported (ordered
separately)
Transceivers supported (ordered
separately)
• ProCurve 10-GbE X2-SC LR Optic
• ProCurve Switch 10-GbE X2-CX4
Transceiver
• ProCurve 10-GbE X2-SC SR Optic
• ProCurve 10-GbE X2-SC ER Optic
• ProCurve 10-GbE CX4 Media Converter
Maximum distance
CX4: 15 m (CX4 cable) or 300 m (media
converter with ribbon MMF)
Notes
Only the two fixed CX4 ports on this module
support ProCurve 10-GbE CX4 Media
Converter (J8439A).
Operating temperature is 32°F to 104°F
(0°C to 40°C) if any X2 10-GbE optic or
transceiver is inserted in any X2 slot.
One 0.5m CX4 cable is included.
• ProCurve Gigabit-SX-LC Mini-GBIC
• ProCurve Gigabit-LX-LC Mini-GBIC
• ProCurve Gigabit-LH-LC Mini-GBIC
• ProCurve Gigabit 1000Base-T Mini-GBIC
Notes
This product requires revision "B" or later
mini-GBICs (product number ends with the
letter "B", e.g. J4858B, J4859B).
When installed in a 5400 chassis, the J8706A
module limits the operating temperature
range of the chassis to 32°F to 104°F
(0°C to 40°C).
Module available mid-2006