Page 2
However, no responsibility is assumed for inaccuracies. Nor does Phoenix International assume any liability arising out of the application or use of any product or circuit described herein. Phoenix International reserves the right to make changes to any product and product documentation in an effort to improve performance, reliability or design.
Drive Hardware Configuration Hard Drive Hardware Configuration Considerations for Installation VMEbus Slot Requirements VMEbus Backplane Requirements Power Supply Requirements Installing the VF2-350-SCW-RHD Drive Software Configuration Hard Drive Software Configuration Terminator Power Configuration Operation Termination Chapter 4 Hard Disk Drive Details...
Fast/Wide SCSI Host Adapter. Together with the processor, a complete system can be installed in only three standard VMEbus system slots. The VF2-350-SCW-RHD provides a removable 3.5 inch low profile disk in a 2 slot 6U VME mod- ule making it very convenient to have removable data storage. The drive used in the VF2-350-SCW-RHD was chosen for compatibility, ruggedness and reliability.
Page 8
UNIT Figure 1-1: VX2-350-SCW-RHD Front Panel VX2-350-SCW-RHD User's Manual...
This chapter describes the overall features and specifications of the VF2-350-SCW-RHD. Features The VF2-350-SCW-RHD incorporates one very compact removable winchester disk drive within a single module. The hard disk drive is a high-performance winchester type with embedded disk drive control electronics. This microproces- sor controlled embedded controller is on the hard disk and is compatible with ANSI X3.131-1986 SCSI commands.
VF2-350-SCW-RHD Specifications The following table provides the specifications of the complete VF2-350-SCW-RHD. Individual disk drive specifications are given in their respective chapters. General Model: VF2-350-SCW-RHD Description: Hard disk drive module compatible with SCSI commands. Interface: Fast Wide SCSI-2 Drive Type: Particular type depends on capacity ordered.
This chapter describes how to configure, install and operate the VF2-350-SCW-RHD mass storage subsystem module. Drive Hardware Configuration The drives on the VF2-350-SCW-RHD can be configured for normal operation as SCSI units 0-15 by setting the front panel switches with a small screwdriver.(See Figure 1-1) The particular configuration of the Unit ID's required depends upon the software and the application operating system.
LED shows a "u" to indicate that the drive is unlocked, spun down and safe to be removed. Once the VF2-350-SCW-RHD has been configured properly and the software has been set up, operation is identical to that of a standard SCSI storage subsystem. No specialized software is required.
If You Have a Problem If you are having a problem with a Phoenix International product, you should call our main number, (714) 283-4800, and ask for Customer Service. Please be prepared to supply as much detail as you can concerning the nature of the problem and the conditions in which the problem appeared.
If a product is found not to be under warranty, we will notify you of the non-warranty situation and provide you with a fixed cost and a schedule for the repair. Non-warranty repairs require that a purchase order be issued to Phoenix International for the amount of the repair before repairs are undertaken.
Need help?
Do you have a question about the VF2-350-SCW-RHD and is the answer not in the manual?
Questions and answers