Retraction - Sentry Saf-T-Vise STV-LP1 Installation, Operation & Maintenance Manual

Insertable tool holders
Table of Contents

Advertisement

Retraction

Maintain a firm grip on the hand knob throughout the hand retraction procedure, and keep body away from the travel path
of the rod/shaft . An unsecured rod/shaft could move outwards forcefully, causing serious injury or death .
1. Remove safety chain .
a. While holding the hand knob firmly, loosen the locking collet bolt .
b. Push the tool in slightly and remove the chain .
2. Retract rod/shaft from pipeline .
a. Retract the rod/shaft completely into the holder .
b. Re-tighten the locking collet bolt to 35 ft-lb (47 .45 Nm) .
3. Slowly close the process isolation valve .
 NOTE
If the process isolation valve has difficulty closing, make sure that the rod/shaft
is completely retracted past the isolation valve .
4. Open the bleeder valve to relieve any trapped pressure .
Support the rod/shaft during removal from the process isolation valve to prevent bending .
5. Remove the holder from the process isolation valve .
Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2
Locking Collet Bolt
Chain Holder
Safety Chain