Changing A Rod/Shaft And Replacing A Seal - Sentry Saf-T-Vise STV-LP1 Installation, Operation & Maintenance Manual

Insertable tool holders
Table of Contents

Advertisement

6. When the rod/shaft is thoroughly clean, wipe the rod/shaft with Molykote 55 lubricant or other silicone/lithium
lubricant .

Changing a Rod/Shaft and Replacing a Seal

Tools needed
ƒ Medium adjustable wrench
ƒ Permanent marker
ƒ ¼" NPT nipple 2"–4" (5–10 cm) in length (for atomizers or quills only)
ƒ Hex key set
ƒ Small pick or screwdriver
ƒ Clean rag
ƒ Seal Installation Tool (for Teflon seals only)
– P/N 2-07815E for 3/8" OD rod/shaft
– P/N 2-07815F for ¼" OD rod
ƒ New seal for holder (Teflon or graphoil as needed)
ƒ Molykote 55 lubricant or other silicone/lithium lubricant
ƒ Anti-seize lubricant
ƒ 320 grit or finer sandpaper
ƒ Cleaner/solvent
1. Remove the rod/shaft .
a. With the holder removed from the line, loosen the locking collet and slide the rod/shaft to the fully inserted
position, leaving 1" (2 .5 cm) between the top of the holder and the adapter lock nut .
b. Tighten the locking collet bolt to 35 ft-lb (47 .45 Nm) .
c. Remove adapter .
ƒ Coupon holder only
– If using a flat coupon, use a permanent marker to mark the rod to show where the edge of the coupon is
oriented .
– Use a medium adjustable wrench to loosen the adapter lock nut .
– Remove both the adapter and the lock nut .
ƒ Atomizer or quill
– If using a quill or atomizer nozzle with a specific orientation, use a permanent marker to mark the shaft to
show which direction the quill or nozzle is oriented .
– If fluid inlet does not have wrench flats, use a ¼" NPT nipple threaded into the fluid inlet adapter to remove
the adapter from the shaft . If the adapter has a multi-port valve, you can use the existing assembly to aid in
removal .
d. Loosen the collet and slide the shaft out of the body of the holder .
2. Separate the upper and lower body of the holder .
a. Holders with Teflon seals use a socket head set screw; holders with graphoil seals use a hex head set screw .
b. Loosen (but not completely remove) the small set screw on the upper body .
Make sure the set screw is loose . Failure to loosen the set screw can cause permanent damage to the holder .
Saf-T-Vise STV-LP1 & Saf-T-Vise STV-LP2
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saf-t-vise stv-lp2