Specification - Mitsubishi Electric Trane NTXWPH06B112AA Service Manual

Indoor unit
Table of Contents

Advertisement

3

SPECIFICATION

Indoor unit model
Power supply
V, phase, Hz
Disconnect switch
Min. circuit ampacity
Fan motor
Airflow
COOL Dry
(Wet)
Super high - High -
HEAT Dry CFM 437 - 381 - 225 - 167 - 140 437 - 381 - 225 - 167 - 140 454 - 367 - 282 - 226 - 155 514 - 410 - 350 - 272 - 201 514 - 410 - 350 - 272 - 201
Med. - Low - Quiet
Moisture removal
Sound level
Cooling dB(A) 40 - 36 - 29 - 23 - 20 40 - 36 - 29 - 23 - 20 44 - 36 - 29 - 24 - 21 44 - 39 - 35 - 31 - 27 44 - 39 - 35 - 31 - 27
Super high - High -
Heating dB(A) 42 - 39 - 29 - 24 - 20 42 - 39 - 29 - 24 - 20 43 - 38 - 32 - 28 - 21 46 - 40 - 37 - 31 - 25 46 - 40 - 37 - 31 - 25
Med. - Low - Quiet
Cond. drain connection O.D. in.
W
Dimensions
D
H
Weight
External finish
Remote controller
Control voltage (by built-in transformer)
NOTE: Test conditions are based on AHRI 210/240.
3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
208/230 V
Indoor unit
(2) OPERATION
Mode
Condition
Standard temperature
Maximum temperature
Cooling
Minimum temperature
Maximum humidity
Standard temperature
Heating
Maximum temperature
Minimum temperature
3-2. OUTLET AIR SPEED AND COVERAGE
Model
Mode
HEAT
NTXWPH06B112AA
COOL
HEAT
NTXWPH09B112AA
COOL
HEAT
NTXWPH12B112AA
COOL
HEAT
NTXWPH15B112AA
COOL
HEAT
NTXWPH18B112AA
COOL
OBHT872
NTXWPH06B112AA NTXWPH09B112AA NTXWPH12B112AA NTXWPH15B112AA NTXWPH18B112AA
A
A
F.L.A
381- 304 - 221 - 167 - 137
381- 304 - 221 - 167 - 137
CFM
(328 - 261 - 190 - 143 - 117)
(328 - 261 - 190 - 143 - 117)
pt./h
0.2
in.
Ib.
Guaranteed voltage (V)
Min. 187
1 phase
60 Hz
DB
80
90
67
70
80
70
Airflow
Function
(CFM)
Dry
437
Dry
381
Wet
328
Dry
437
Dry
381
Wet
328
Dry
454
Dry
424
Wet
364
Dry
514
Dry
437
Wet
376
Dry
514
Dry
437
Wet
376
208/230 , 1 , 60
15
1.0
0.65
424 - 304 - 221 - 167 - 137
(364- 261 - 190 - 143 - 117)
0.6
1.9
5/8
36-7/16
9-3/16
12 (+ 11/16)
29
Munsell 1.0Y 9.2/0.2
Wireless type
12 - 24 VDC
208
230
Max. 253
Intake air temperature (°F)
Indoor
WB
67
73
57
78%
60
67
60
Air speed
Coverage (ft.)
(ft./s)
19.5
29.8
17.0
26.1
14.6
22.5
19.5
29.8
17.0
26.1
14.6
22.5
20.3
31.0
19.0
29.0
16.2
24.8
23.0
34.9
19.5
29.8
16.7
25.6
23.0
34.9
19.5
29.8
16.7
25.6
5
437 - 355 - 304 - 262 - 225
437 - 355 - 304 - 262 - 225
(376 - 305 - 261 - 225 - 194)
(376 - 305 - 261 - 225 - 194)
4.0
Outdoor
DB
95
115
14
47
75
-13
● The air coverage is the figure up to
the position where the air speed is
1 ft./s,
when air is blown out horizontally
from the unit properly at the High
speed position.
The coverage should be used only
as a general guideline since it var-
ies according to the size of the
room and furniture arranged inside
the room.
5.1
WB
43
65
-14