7.3 Installation position
The following installation positions are permissible. The pipeline routing shown
illustrates the basic layout.
If filling the stroking chambers via X
position, then
the filling
position 2.
To prevent unexpected actuation and damage, the stroking chambers must be air
bled via the ports X
, X
1
For installation position 4 and 10 (drive shaft upwards), you need the additional
air bleed port R
in the flange area. This port is not provided in the standard
1
version and must be stated in plain text when ordering.
to X
is not possible in the final installation
1
4
must be effected before installation, e.g. in installation
, or X
, X
depending on the installation position.
2
3
4
RE 92004-01-B/05.2017, A4VG Series 40, Bosch Rexroth AG
Installation
31/68