28/60
Installation
Bosch Rexroth AG, A10VGT Series 11, RE 92770-01-B/11.2016

7.3 Installation position

The following installation positions are permissible. The piping layout shown
illustrates the basic layout.
If filling the stroking chambers via X
position, then this must be carried out before installation, e.g. in installation
position 2.
To prevent unexpected actuation and damage, the stroking chambers must be air
bled via the ports X
and X
1

7.3.1 Below-reservoir installation (standard)

Below-reservoir installation means that the axial piston unit is installed outside
of the reservoir and below the minimum fluid level of the reservoir.
Recommended installation position: 1 and 2.
1
h
t min
h
min
X
X
1,
2
R
T
Fig. 8: Below-reservoir installation A10VGT with installation position 1-2
, T
T
Highest drain port
1
2
R
Air bleeding
S
Suction port
X
, X
Control pressure port
1
2
Table 8: Below-reservoir installation
Installation position
1 (drive shaft horizontal)
2 (drive shaft horizontal)
to X
is not possible in the final installation
1
2
depending on the installation position.
2
2
SB
S
1
h
t min
h
min
SB
Air bleeding
the housing
R
SB
h
t min
h
min
T
2
S
Minimum required immersion depth
(200 mm)
Minimum required distance to
reservoir bottom (100 mm)
Baffle (baffle plate)
Air bleeding
Filling
the stroking
chamber
X
, X
S + T
+ X
1
2
1
S + T
2
+ X
1
2