Advertisement

Quick Links

n
E-mail:
PL1015WASH
Address: No. 43, Yunfeng Road, Xiuquan Street,
Huadu District, Guangzhou, China

Advertisement

Table of Contents
loading

Summary of Contents for Fly Dragon Light Sky PL1015WASH

  • Page 1 E-mail: PL1015WASH Address: No. 43, Yunfeng Road, Xiuquan Street, Huadu District, Guangzhou, China...
  • Page 2: Table Of Contents

    Contents 1. Safety information........................2 2. Technical information......................7 3. Attachment and body size.......................8 4. Installation and connecting.....................9 5. Control panel.........................12 6. Menu setting..........................13 7. Channel function........................15 8. Circuit connecting diagram....................25 9. Cleaning and maintenances....................26 10. Troubeshooting........................27 11. Duty exonerative and copyright protection..............28 Congratulations on choosing our company product! We thank you for your custom.
  • Page 3: Safety Information

    SAFETY INFORMATION ■This lighting fixture is for professional use only - it is not for household use. Make sure all parts for fixing the projector are in a good state of repair. Make sure the point of anchorage is stable before positioning the projector. The safety chain must be prgperly hooked onto the fitting and secured to the framework.
  • Page 4 60℃ The maximun temperature that can be reached on the external surface of the fitting, in a thermally steady state,is 60℃。 Avoid contact bypersons and materials. Allow the fixture to cool for at least 5 minutes before handling. ■The light source The light source in this xture shall be replaced by the manufacturer or its service agent or similar qualication.
  • Page 5: Technical Information

    TECHNICAL INFORMATION ● Power supplies available AC100-240V∽,50/60Hz ● Power 100W,PF 0.988 ● LED chip: Tian xin 15W,RGBW 4 in 1 LED chip ● :10PCS. LED QTY ● : 50000h Average life ● : Color RGBW macro color system.LED can be controlled pixel by pixel, delivering versatile effects。...
  • Page 6 Distance,spot diameter and illumination diagram 8°lens illumination(Lux) 1145 2837 1501 85.8 4300 1864 1093 RGBW 5674 3143 1950 1024 12° Distance(m) 0 Diameter(m) 1.56 3.06 Distance,spot diameter and illumination diagram 15 ° lens illumination(Lux) 520.8 225.4 130.8 71.2 1382 604.8 326.9 168.3 100.6...
  • Page 7 Distance,spot diameter and illumination diagram 22° lens illumination(Lux) 323.8 132.8 70.8 36.8 784.3 318.5 166.9 84.8 154.5 64.1 33.9 16.5 954.5 376.9 200.5 102.5 RGBW 1640 653.5 177.5 26° Distance(m) 0 2.33 4.22 5.62 Diameter(m)
  • Page 8 Distance,spot diameter and illumination diagram 45° lens illumination(Lux) 108.2 43.3 27.6 107.3 68.3 52.6 19.8 14.1 133.5 48.5 RGBW 226.8 137.1 76.9 47° Distance(m) 0 Diameter(m)
  • Page 9: Attachment And Body Size

    ATTACHMENT AND BODY SIZE power cord ◆Each of the eight stage lights delivers a power cord and a signal line.
  • Page 10: Installation And Connecting

    INSTALLATION AND CONNECTING Installing the projector- Fig. 3 The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall. WARNING:with the exception of when the projector is positioned on the floor, the safety rope must be fitted. This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.
  • Page 11 POWER END POWER IN Wire Color Wire Color Conductor Symbol (EU models) (US models) black live brown neutral blue white green ground(earth) yellow-green The stage lighting power supply can not be more than 10pcs pre line ● connection to the eiectricty mains must be carried out by a qualified electrical ●...
  • Page 12 OUT IN DMX IN DMX - output DMX-input 1 - Shield - Shield 2 - Signal (-) - Signal (-) - Signal (+) - Signal (+) - Not connected - Not connected - Not connected - Not connected all the projectors are together The projector dn’t touch each other or plinth).
  • Page 13: Control Panel

    CONTROL PANEL ENTER Up arrowhead : page up Down arrowhead : page down RIGHT LEFT Left arrowhead : reduce Right arrowhead : increase Enter : OK function Exit : in the choice screen DOWN...
  • Page 14: Menu Setting

    MENU SETTING note Ⅰ menu Ⅱ menu Main menu Address ADD:000- Channel 45CH 25CH 18CH 40CH Hold Black Green Blue White R&G R&B DMX.Fuc R&W When the signal is disconnected, the lamp remains in its final state G&B G&W Setting B&W Pro1 Pro2...
  • Page 15 note Ⅰ menu Ⅱ menu Main menu W000-255 M000-255 FSCE Z000-255 Setting Return Dim 000- 255 Shu 000- 255 Red 000 - 255 Gree 000- 255 List Information Blue 000 - 255 Whit 000- 255 Macr 000- 255 Eff 000- 255 EF - S 000- 255 V1.00 Vers...
  • Page 16: Channel Function

    CHANNEL FUNCTION channel(Standard 9CH) Function Percentage Channel 0-255 Dimmer 0-255 Shutter 0-255 、Red -1 0-255 Green 、Green -1 0-255 Blue 、Blue -1 0-255 White 、White -1 0-255 Macro 0-255 Effect NO Function 6-10 Effect1 11-15 Effect2 16-20 Effect3 21-25 Effect4 26-30 Effect5 31-35...
  • Page 17 Function Channel Percentage 126-130 Effect25 131-135 Effect26 136-140 Effect27 141-145 Effect28 146-150 Effect29 151-155 Effect30 156-160 Effect31 161-165 Effect32 166-170 Effect33 171-175 Effect34 176-180 Effect35 181-185 Effect36 186-190 Effect37 191-195 Effect38 196-200 Effect39 201-205 Effect40 206-210 Effect41 211-215 Effect42 216-220 Effect43 211-255 NO Function...
  • Page 18 channel(Extended 45CH) Channel Function Percentage Dimmer 0-255 0-100 Shutter 0-255 0-100 0-255 Red 1 0-100 0-100 0-255 Green 1 0-100 0-255 Blue 1 0-100 0-255 White 1 0-255 0-100 Red 2 0-255 0-100 Green 2 0-255 0-100 Blue 2 0-255 0-100 White 2 0-255...
  • Page 19 Channel Function Percentage Blue 8 0-255 0-100 White 8 0-255 0-100 0-255 Red 9 0-100 0-100 0-255 Green 9 0-100 0-255 Blue 9 0-100 0-255 White 9 0-100 0-255 Red 10 0-255 0-100 Green 10 0-255 0-100 Blue 10 0-255 0-100 White 10 Macro...
  • Page 20 Percentage Channel Function 101-105 0-100 Effect20 106-110 0-100 Effect21 111-115 0-100 Effect20 0-100 Effect23 116-120 0-100 121-125 Effect24 0-100 126-130 Effect25 0-100 Effect26 131-135 Effect27 136-140 0-100 Effect28 141-145 0-100 Effect29 0-100 146-150 Effect30 151-155 0-100 156-160 Effect31 161-165 Effect32 166-170 Effect33 171-175...
  • Page 21 channel( 25CH) Function Percentage Channel 0-255 Dimmer 0-255 Shutter 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 Macro 0-255 Effect NO Function 6-10 Effect1 11-15 Effect2 16-20 Effect3 21-25 Effect4...
  • Page 22 Function Channel Percentage 81-85 Effect16 86-90 Effect17 91-95 Effect18 96-100 Effect19 101-105 Effect20 106-110 Effect21 111-115 Effect22 116-120 Effect23 121-125 Effect24 126-130 Effect25 131-135 Effect26 136-140 Effect27 141-145 Effect28 146-150 Effect29 151-155 Effect30 156-160 Effect31 161-165 Effect32 166-170 Effect33 171-175 Effect34 176-180 Effect35...
  • Page 23 CHANNEL( 18CH) Percentage Function Channel 0-255 Dimmer 0-255 Shutter 0-255 0-255 Green 0-255 Blue 0-255 White 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 Effect NO Function 6-10 Effect1 11-15 Effect2 16-20 Effect3 21-25 Effect4 26-30 Effect5 31-35 Effect6 36-40...
  • Page 24 Percentage Channel Function 121-125 Effect24 126-130 Effect25 131-135 Effect26 136-140 Effect27 141-145 Effect28 146-150 Effect29 151-155 Effect30 156-160 Effect31 161-165 Effect32 166-170 Effect33 171-175 Effect34 176-180 Effect35 181-185 Effect36 186-190 Effect37 191-195 Effect38 196-200 Effect39 201-205 Effect40 206-210 Effect41 211-215 Effect42 216-220 Effect43...
  • Page 25 CHANNEL(40CH) Channel Percentage function note 0-255 0-255 Green 0-255 Blue 0-255 White 0-255 0-255 Green 0-255 Blue 0-255 White 0-255 0-255 Green 0-255 Blue 0-255 White 0-255 0-255 Green 0-255 Blue 0-255 White 0-255 0-255 Green 0-255 Blue 0-255 White 0-255 0-255 Green...
  • Page 26: Circuit Connecting Diagram

    CIRCUIT CONNECTING DIAGRAM...
  • Page 27: Cleaning And Maintenances

    CLEANING AND MAINTENANCES ■1.In order to ensure the projector could work normally. It should be kept clean always . The lens should also be regularly cleaned to maintain an optimum light output. Do not use any type of solvent on lens. It will damage the projector. ■2.Suggestion: The continue usage of the light don't exceed 4 hours.
  • Page 28: Troubeshooting

    TROUBESHOOTING It is recommended some solution for some normal trouble shooting. Any inextricability problems should always be handling by the professional person. Disconnect the power supply before maintenance the light. ■ LED off 1.Please check if install the suitable voltage 2.Please check whether the led will reach the end of their life can explode;...
  • Page 29: Duty Exonerative And Copyright Protection

    DUTY EXONERATIVE AND COPYRIGHT PROTECTION ◇The lamp belongs to consumption products that is not guarantee to keep it in good repair. ◇Any products broken that didn't according to the instruction is not guarantee to keep it in good repair. ◇The commentary for all the instruction belongs to the supplier in final. ◇No authorize can't copy.

Table of Contents