Operation Manual (EN) Translation of the german original manual ® WOB-L Piston pumps Models: ► 2511C-02 ► 2511B-01 2511 2017-05-16...
Page 2
Reprinting or reproduction of this manual, including extracts, is not allowed without the prior written permission of Co. Gardner Denver Thomas GmbH. All rights under the copyright laws are expressly reserved by Co. Gardner Denver Thomas GmbH. We reserve the right to make changes and amendments.
Contents Contents Important Information ......................4 General Information ........................4 Target Groups ........................... 4 Intended Use ..........................4 Use for an Unauthorized Purpose .................... 4 Safety Devices .......................... 5 Meaning of the Warning notes ....................5 Product Standards, Safety Regulations ..................5 Basic Safety Instructions .......................
Important Information Important Information General Information ® The WOB-L Piston Pumps conform to the following directives: 2006 / 42 / EC Machinery Directive 2014 / 30 / EU Electromagnetic Compatibility Directive 2014 / 68 / EU Pressure Equipment Directive 2014 / 29 / EU Simple Pressure Vessels Directive The CE sign is located on the rating plate.
Important Information Safety Devices Measures such as the following are for the safety of the operating personnel: electrical connection with a protective conductor (operating mode S1) and an earthing plug Motor protection device (thermal) “Hot Surface" label on the pump - warning notice ®...
Basic Safety Instructions Basic Safety Instructions General Information Warning notices must be observed. Disregarding them may lead to damage to health and property. ® The WOB-L Piston Pumps must be operated by personnel who can detect impending dan- gers and take action to prevent them from materialising. ®...
Basic Safety Instructions Hazardous Substances ACHTUNG ! ® The operating company bears the responsibility for the use of the WOB-L Piston Pumps. Hazardous substances in the gases to be pumped can cause personal injuries and property damage. Pay attention to the warning notices for handling hazardous sub- stances.
Description Protection measure against liquids in the pump 3.2.1 Condensate separator (Suction side) If the possibility of penetration of larger liquid quantities we recommend the installation of a larger collection vessel (eg. Woulff bottle). Areas of Application ® The WOB-L Piston Pumps are intended to: Pumping and compressing neutral and aggressive gases and vapours.
It is the responsibility of the user to determine the suitability of the product for the intended use and the user as- sumes all risk and liability whatsoever in connection therewith. Gardner Denver Thomas GmbH does not warrant, guarantee or assume any obligation or liability in connection with this information.
Installation and Operation Installation and Operation Unpacking ® Carefully unpack the WOB-L Piston Pump. Check the pump for: Transport damage, Conformity with the specifications of the supply contract (type, electrical supply data), Completeness of the delivery. Please inform us without delay if there are discrepancies between the delivery and the con- tractually agreed scope of delivery, or if damage is detected.
Installation and Operation CAUTION ! Use only for compressed air applications suitable conduit systems! Operation CAUTION ! ® Observe the basic safety instructions when using the WOB-L Piston Pump, chapter 2. 5.3.1 Start-up Make sure that when you start the pump, which may arise in the connection lines con- densates, cannot penetrate into the pump.
Maintenance and Servicing Maintenance and Servicing ® WOB-L Piston pumps are 100% oil-free. The piston and cylinder of the pump are lubricated maintenance free. All bearings are sealed and permanently lubricated. Maintenance Performed by the User WARNING ! Only perform the work that is described here, and that which is permitted to be done by the user.
Troubleshooting Troubleshooting ® During the warranty period, intervention in the WOB-L Piston Pumps and accessory com- ponents may only be made by manufacturing firm. Remedy Trouble Cause with: Qualified No power supply Check electrical installation electrician Pump does not start Service Motor defective Exchange...