Operation Manual / 4 Product description / A100-M axial
8 Disassembly and assembly / 8.3 Removing / Installing air-inlets
8.3

Removing / Installing air-inlets

Removing the filter silencer
Dismantle insulation as far as necessary.
u
Fig. 28: Removing / installing the filter silencer
1. Loop lifting gear through the fin on the filter silencer and secure to the eyelets at the rear
with shackles (90195).
2. Loosen nuts (72027) and remove with washers (72028).
Remove and put down filter silencer.
u
Installing the filter silencer
The installation of the filter silencer is carried out in reverse order.
Tighten nuts (72027) to the specified tightening torque.
u
Part number
27027
Table 31: Tightening torque (27027)
© Copyright 2019 ABB. All rights reserved.
A170-M
M18
170 Nm
HZTL4033_DE
A175-M
M20
220 Nm
Revision C
February 2019