Hoshizaki KM-420MAJ Instruction Manual page 32

Modular crescent cuber
Hide thumbs Also See for KM-420MAJ:
Table of Contents

Advertisement

For Non-Hoshizaki Dispenser Units
Bin Control Setting
1
(Factory Default)
2
3
4
5
Confirm that the final ice level location does not allow for icemaker movement,
water leakage, or ice overflow.
The ice level must be lower than the top of the dispenser unit. Also, be sure the top
kit or top kit riser (if applicable) are clear from the bin control lens sensing area.
Full Bin Measured Distance
(Shutdown Distance)
Measure from the bottom of
the compressor base (bin
control lens) to the preferred
full bin level of ice; refer to the
dispenser instruction manual.
Set Bin Control Setting at or Below Maximum Full
Bin Level of Ice (Shutdown Position) Shown Here
Control Board
Turn dial to adjust to setting
that matches Full Bin Measured
Distance (Shutdown Distance)
Bin Control Ice Level Settings
Shutdown Distance From Bin Control Lens
(Restart is 4 in. (102 mm) below shutdown distance)
Do not adjust dispensers to this setting. 254 mm (10")
Icemaker
Bin Control Lens
Top Kit
Icemaker Restart Level
(4" (102 mm) below preferred
full bin level of ice)
Non-Hoshizaki
Dispenser Unit
Bin Control Setting
305 mm (12")
406 mm (16")
508 mm (20")
610 mm (24")
WARNING
NOTICE
32
Bin Control
Lens
Setting #1
Setting #2
Setting #3
Setting #4
Setting #5
Maximum Full Bin Level of
Ice (Shutdown Position).
WARNING! Do not adjust
bin control setting above
this level.
Factory Default for Standard
Ice Storage Bins
WARNING! Do not use this
setting with dispensers.
Fig. 17

Advertisement

Table of Contents
loading

Table of Contents