PSP05-A
PSP05-C
The motion sensor PSP05 has PIR function, based on Z-Wave
technology.
PSP05-B
PSP05-D
TM
1
This device is a Security Enabled Z-Wave Plus Product. Z-Wave
wireless communication protocol designed for home automation,
specifically to remotely control applications in residential and light
commercial environments. The technology uses a low-power RF radio
embedded or retrofitted into home electronics devices and systems,
such as lighting, home access control, entertainment systems and
household appliances.
This product can be included and operated in any Z-Wave
with other Z-Wave
TM
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
The device adopt the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
CAUTION
– replacement of a battery with an incorrect type that can defeat a
safeguard (for example, in the case of some lithium battery types);
– disposal of a battery into fire or a hot oven, or mechanically crushing
or cutting of a battery, that can result in an explosion;
– leaving a battery in an extremely high temperature surrounding
environment that can result in an explosion or the leakage of flammable
liquid or gas;
– a battery subjected to extremely low air pressure that may result in an
explosion or the leakage of flammable liquid or gas
The marking information is located at the bottom of the apparatus.
TM
500 series chip, when your Z-Wave
TM
500 series devices. The
TM
is a
TM
network
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSP05-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio Technology Corporation PSP05-A

  • Page 1 All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. PSP05-A PSP05-B The device adopt the Z-Wave 500 series chip, when your Z-Wave network system is all made by Z-Wave 500 series devices.
  • Page 2: Specification

    For Instruction to http:// (TW/KR/Thai/SG) RF Maximum Power +5dBm Dimension 89*83*62 91.4g (PSP05-A), Weight 96.0g (PSP05-D) IP classification IPX4 (PSP05-A or PSP05-D) Location Indoor or outdoor Operation temperature -10 to 40° C Humidity 85%RH max FCC ID RHHPSP05 overview Marking CE/NCC ...
  • Page 3: Function Description

    2. IDs are excluded and all settings will reset to factory default. Add to/Remove from Z-Wave Network 1. Have Z-Wave Controller entered association mode. There are two keys in the device, one is tamper key, another is a 2. Pressing button one time to enter the association button.
  • Page 4: Power Up Procedure

    * Timing Report: Beside the event triggered could report message, the device also Z-Wave Message Report support the timing unsolicited report of the status. Battery level report: Every 6 hours report once in default. • When the PIR motion triggered, the device will report the trigger event It could be changed by setting the configuration NO.
  • Page 5: Security Network

    * Wake When the event triggered, the device will report the messages to the When the device power on, the device will wake about 20 seconds. In nodes in the group 1. The messages also include the battery level. The this duration, the controller can communicate with the device.
  • Page 6: Battery Installation

    Battery Installation Z-Wave Configuration Settings When the device reports the low battery message, users should Notice: replace the battery. The battery type is CR123A, 3.0V. * All of the configuration, the data size is 1. * The configuration mark with star(*), means after the remove the setting still keep, don't reset to factory default.
  • Page 7 Name Description Name Description Def. Def. Valid Valid Setting the BASIC command value to turn on Bit4: Disable delay 5 seconds to turn off the the light. -1(0xFF) means turn on the light. light, when door/window closed. (1:Disable, For dimmer equipment 1 to 100 means the 0:Enable) Basic Set light strength.
  • Page 8: Fcc Interference Statement

    After turn on the lighting, setting the delay environmental safe recycling. Turn Off time to turn off the lighting when the PIR Philio Technology Corporation Light 0 ~ 127 motion is not detected. 8 seconds per tick, 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City Time default tick is 4 (32 seconds).
  • Page 9 uses and can radiate radio frequency energy and, if not installed and your health and well-being. used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no When replacing old appliances with new once, the retailer is legally guarantee that interference will not occur in a particular installation.

This manual is also suitable for: