Smeg KDD90VX Manual page 17

Table of Contents

Advertisement

Can be washed in the dishwasher. It must be washed when
months, or more frequently if use is particularly intense. Guaranteed to operate after washing for up to a
maximum of 5 times before requiring replacement. The Alarm signal, if it has been activated, only appears
when the Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a
later date.
• Turn the Lights and the Suction Motor off.
• Press and hold button E for 2 seconds:
• C flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• C flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press and hold button G for 2 seconds.
Changing the Filter
• Remove the comfort panel.
• Remove the Metal grease filters.
• Remove the metal filter stops from the grease filter and
clean the saturated activated charcoal odour filter.
• Replace the clean activated charcoal filter, hooking it
back up to the grease filter using the metal filter stops.
• Replace the Metal grease filters.
• Close the comfort panel.
Warning: This appliance is fitted with a white LED lamp classed as 1M
according to EN 60825-1: 1994 + A1:2002 + A2:2001 standards; maxi-
mum optical power emitted @439nm: 7µW. Do not look directly at the
light through optical devices (binoculars, magnifying glasses...).
• For replacement contact technical support. ("To purchase contact tech-
nical support")
EN
Activated Charcoal Filter (Recirculation Version)
Lighting unit
is displayed or at least once every 4
3 36

Advertisement

Table of Contents
loading

Table of Contents