• This manual gives general information on the location of the temperature sensing thermocouple. If the heater is part of a Samuel Jackson Steamroller System, more detailed information will be shipped to you under separate cover specifically for your system.
When using a moisture restoration system in cold regions, a source of hot air separate from the Humidaire Unit is helpful for pre-warming the Steamroller, Moisture Condenser, or lint slide jacket. The HG-1-1401A heater is built for this purpose. It includes PLC combustion controls with diagnostics. It has built-in temperature controls with a 2-HP fan and motor combination capable of delivering up to 3,000 CFM of tightly controlled, reliable hot air.
Page 7
The TESTS and SETUP programs can be activated by a qualified service man or trained user to test the heater and make custom settings. They are always performed in the Samuel Jackson factory before shipment of a new heater and occasionally in the field, when necessary, for troubleshooting.
ERROR & ALARM LOGGING SYSTEM The ERROR and ALARM LOGGING SYSTEM is designed to make troubleshooting easier for both the user and Samuel Jackson service personnel. This system remembers the last 500 ERRORS and ALARMS, thus showing a history of past problems. The Alphanumeric display DMD located in the LOCAL PANEL (See below) shows the code number for the ERROR or ALARM along with the month, day and time of occurrence.
Page 16
SELECT button is pressed to clear ERROR 140. ERROR 141 FAN RELAY FAILED TO OPEN WHEN AIR FLOW WAS ABSENT: Samuel Jackson heaters are provided with a fan interlock to provide immediate shutdown of the heater if the fan turns off.
Page 21
LOGS TESTS Unlike earlier Samuel Jackson combustion products with PLC’s where the test program had to be done in sequence, the new TESTS allows the user the choice of which tests to perform. Observe the display for test program prompts.