SAMUEL JACKSON HG-1-1401A Service Manual

1-million btu/hr gas-fired heater

Advertisement

Quick Links

HG-1-1401A
1-Million Btu/Hr
Gas-Fired Heater
Service and Operation Guide

Advertisement

Table of Contents
loading

Summary of Contents for SAMUEL JACKSON HG-1-1401A

  • Page 1 HG-1-1401A 1-Million Btu/Hr Gas-Fired Heater Service and Operation Guide...
  • Page 2 PAGE -1 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 3: Table Of Contents

    Dimensions for HG-1-1401 Heater ..........37 Warranty Information ..............40 Electrical Controls and Your Safety .......... 41 Copyright © 2005 SAMUEL JACKSON, INCORPORATED. All rights reserved. PAGE 0 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 4 • This manual gives general information on the location of the temperature sensing thermocouple. If the heater is part of a Samuel Jackson Steamroller System, more detailed information will be shipped to you under separate cover specifically for your system.
  • Page 5: Introduction

    When using a moisture restoration system in cold regions, a source of hot air separate from the Humidaire Unit is helpful for pre-warming the Steamroller, Moisture Condenser, or lint slide jacket. The HG-1-1401A heater is built for this purpose. It includes PLC combustion controls with diagnostics. It has built-in temperature controls with a 2-HP fan and motor combination capable of delivering up to 3,000 CFM of tightly controlled, reliable hot air.
  • Page 6: Heater Operation

    The STATUS light will remain on throughout this process. After approximately 20 seconds, the burner will attempt ignition. If ignition fails, the heater controls will automatically make two more attempts following appropriate air purge delays. PAGE 3 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 7 The TESTS and SETUP programs can be activated by a qualified service man or trained user to test the heater and make custom settings. They are always performed in the Samuel Jackson factory before shipment of a new heater and occasionally in the field, when necessary, for troubleshooting.
  • Page 8 TO ADJUST TEMPERATURE SET POINT AIR SETPOINT (SP) (SP) PRESS IN AIR SP BUTTON AND TURN +/- SELECTOR SWITCH Setting Air Temperature Set Point (SP) 4376 PAGE 5 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 9 It is better to change the speed of the fan to get close to the desired air volume than severely gating down the air flow from an over sped fan. Variable pitch pulley PAGE 6 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 10: Error & Alarm Logging System

    ERROR & ALARM LOGGING SYSTEM The ERROR and ALARM LOGGING SYSTEM is designed to make troubleshooting easier for both the user and Samuel Jackson service personnel. This system remembers the last 500 ERRORS and ALARMS, thus showing a history of past problems. The Alphanumeric display DMD located in the LOCAL PANEL (See below) shows the code number for the ERROR or ALARM along with the month, day and time of occurrence.
  • Page 11: Other Logs - "Flame On Timer

    The +/- switch is now used to scroll from month to month. When you are finished viewing the times, press SELECT to quit the FLAME ON TIMER step, then use +/- to select BACK. Press SETUP to exit the LOGS. PAGE 8 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 12 CONSTANT AIR TEMP > 5 MINUTES. CHECK THERMOCOUPLE WIRING AND THERMOCOUPLE INPUT CARD. POWER FAULT DURING OPERATION. LOW PLC BATTERY. PLC BATTERY BACKUP DISABLED. REPLACE BATTERY! PAGE 9 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 13: Error & Alarm Explanations

    Note: Errors that have an * in front of them can be temporarily bypassed. See the bypass routine explanation at the end of this section for more details. PAGE 10 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 14 4.5 PSI. Check for malfunction of the gas pressure regulator (GPR). The GHPS is set to 120 inches water column (about 4.5 PSI). PAGE 11 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 15 This can be easily cleaned by removal of the lower housing of the valve (with the gas supply turned off). Contact the factory for technical assistance if required. PAGE 12 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 16 SELECT button is pressed to clear ERROR 140. ERROR 141 FAN RELAY FAILED TO OPEN WHEN AIR FLOW WAS ABSENT: Samuel Jackson heaters are provided with a fan interlock to provide immediate shutdown of the heater if the fan turns off.
  • Page 17 BOTTOM of the control cabinet. A spark plug wire routed incorrectly in the control cabinet can interfere with the operation of the PLC and other electronic components. PAGE 14 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 18 PLC are in working order. Check for disconnected thermocouple, thermocouple wiring problem and connections to the thermocouple input card on the PLC. PAGE 15 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 19 - Use the START/STOP switch at the LOCAL PANEL in the heater. Turn it to the left (O) 3 times. - Press the SELECT button to clear the ERROR and attempt to restart the heater. PAGE 16 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 20: Tests Explanation

    TESTS can only be accessed when the heater is off and not during the heater’s normal gas leak test. To access TESTS when the heater is doing its leak test, power cycle the panel. PAGE 17 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 21 LOGS TESTS Unlike earlier Samuel Jackson combustion products with PLC’s where the test program had to be done in sequence, the new TESTS allows the user the choice of which tests to perform. Observe the display for test program prompts.
  • Page 22 Adjust vanes evenly Burner body access door shown removed allowing access to the air vanes. PAGE 19 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 23 Rotate the three color rings so the tabs are in the positions shown here GVM Gas Valve Motor adjustment PAGE 20 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 24 (PV) line behind the SSOV block will have to be disconnected to remove the SSOV block. Contact the factory for technical assistance. GPG1 SSOV block Screen on inlet to SSOV block PAGE 21 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 25 To exit the test program, kill power or press SELECT and turn the +/- switch to BACK. Press SELECT button once. The STATUS light should stop blinking. To operate the burner normally, operate the START-STOP (O - I). PAGE 22 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 26: Setup Explanation

    The battery may be replaced at any time, even during the heater’s operation, without adversely affecting the system. Press SELECT to proceed. PAGE 23 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 27 If the tuning has been corrupted or changed and a return to the original factory setting is desired, set RATE to 020. PAGE 24 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 28: Stub-Ups

    NATURAL GAS OR PROPANE. 6 TO 20 PSI, 0.4 TO 1.7 BARS. SEE DRAWING 14-1899 IN MANUAL FOR NOMINAL RECOMMENDED PIPE SIZES. * FOLLOWING SUPPLIED WITH HEATER PAGE 25 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 29 TYPE J THERMOCOUPLE WIRE - 50 FEET PAGE 26 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 30 PAGE 27 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 31 PAGE 28 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 32 C PU Direc t LOG IC Koyo N.C . N.C . TE RM POR T1 POR T2 R UN       S TOP PAGE 29 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 33: Proper Grounding

    The earth ground rod should be within 25’ of the heater control cabinet. • Do not connect Heater ground to the gin’s common ground. • Grounding of HG-1-1401 PAGE 30 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 34: Gas Piping

    Quincy, Mass. 02269. This reprint of material is not the complete and official position of the NFPA on the referenced subject which is represented only by the standard in its entirety. PAGE 31 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 35 PAGE 32 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 36 PAGE 33 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 37 LOG IC Koyo N.C . N.C . TE RM PORT1 PORT2 RUN       S TOP 4761 Heater Electrical Cabinet Component Labels PAGE 34 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 38 Heater Gas Train Component Labels PAGE 35 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 39: Component List

    GAS PRESSURE REGULATOR OUTSIDE 21347, 143-80-2HP CABINET GAS VALVE MOTOR WITH VALVE LOWER CABINET 21330, 46050-3 DMA30B120 (MOTOR) 21608, D237614 DMK710/6 (VALVE) IGNITER PLUG BURNER 12398A, CA475 PAGE 36 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 40 DOUBLE SAFETY SHUT-OFF GAS LOWER CABINET VALVES 21326, D224843 DMV-D702/6 THERMOCOUPLE (AIR) DISCHARGE AIR 16900C, EXPOSED TIP, 8 INCH SURFACE MOUNT THERMOCOUPLE BURNER BODY 20513A, TYPE J, PSW-J-5/16-84-SS PAGE 37 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 41 PAGE 38 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 42 PAGE 39 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 43 PAGE 40 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...
  • Page 44: Electrical Controls And Your Safety

    The modifier of the controls assumes all liability for these consequences. Samuel Jackson, Incorporated 3900 Upland Avenue Lubbock, Texas 79407 806-795-5218 PAGE 41 of 41 HG-1-1401A GAS-FIRED HEATER © SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED...

Table of Contents