Troubleshooting

Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this trou-
bleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby's Toll Free Number 1-800-263-2629 for assistance.
PROBLEMS
PROBLEM
1) Unit will not operate.
2) Dehumidifying capacity
(moisture removal) low.
3) Relative Humidity setting not
reached after long period of
operation.
Before attempting to clean and/or service this unit, always
disconnect the power supply cord from the electrical supply outlet.
1) DO NOT use gasoline, benezene, paint thinner, or any other chemicals
to clean this unit, as these substances will damage/deform both plastic
components and luster finish.
2) Never attempt to clean the unit by pouring water directly over any of the
surface areas, as this will cause deterioration of electrical components
and wiring insulation.
3) Use only a mild dish washing detergent, lukewarm water, and a soft
cloth to wipe the exterior surface of the unit and dry thoroughly.
When the dehumidifer is not being used for long time periods, please fol-
low these instructions:
1) Disconnect the power cord from the power supply.
2) Empty the water tank and wipe (clean) thoroughly.
3) Clean air filter thoroughly.
4) Re-package the unit in the original carton.
5) Store the unit upright in a dry location.
POSSIBLE CAUSE
POSSIBLE CAUSE
• Check power cord connection.
• Check electrical outlet for blown fuse.
• Check if water tank is full (if yes, empty).
• Check water tank is properly installed.
• Air filter is dirty and/or blocked.
• Ambient (room) temperature too low (below 5°C/41°F).
• Poor air flow circulation/obstruction of front grill.
• Relative humidity in surrounding environment very low.
• Check all doors and windows are closed.
• Area/room is too large for the capacity of the
dehumidifier.
9