Care And Maintenance; Error Codes; Long Term Storage - Danby DDR070BBPBDB Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

CARE & MAINTENANCE
AIR FILTER
The fi lter indicator will illuminate after 250 hours of
use, indicating that the fi lter should be cleaned.
Remove the fi lter from the back of the appliance.
Use a vacuum to remove dust from the fi lter or wash
with warm water and mild detergent. Ensure the
fi lter is completely dry before replacing it in the
appliance. Press the fi lter button to reset the fi lter
indicator.
Note: Do not operate the appliance without the air
fi lter installed.

LONG TERM STORAGE

Before removing the appliance from service for
the year, operate the appliance on high fan mode
for half a day to ensure that the inside of the
appliance is dry. This will help avoid the growth of
mold or mildew inside the appliance. Ensure the
fi lter is clean and dry. Secure the power cord with
the power cord strap as per the below. Store the
appliance upright and covered in a dry location.
CLEANING
To avoid possible electric shock, ensure that the
appliance is unplugged before performing any
cleaning or maintenance.
The outside of the appliance can be wiped clean
with a soft cloth or with a lukewarm, damp cloth if
necessary.
Do not use gasoline, benzene, thinner or any
other chemicals to clean this appliance as these
substances can cause damage to the fi nish and
deformation of plastic parts.
Never pour water directly onto the appliance as this
will cause deterioration of electrical components
and wiring insulation.
Ensure that the drain ports on the interior of the
appliance and the drain ports on the back of the
appliance are free of dirt and calcium build up.

ERROR CODES

If the display panel shows any of the below error
codes, unplug the appliance, let it stand for 5-10
minutes and then plug it back in. If the error
persists, call for service.
AS - Humidity sensor error
ES - Temperature sensor error
EC - Can indicate that the appliance is either too
hot or too cold to function properly. Ensure that the
ambient room temperature is between 5°C (41°F)
and 35°C (95°F).
E3 - Control panel error
P2 or Eb - Bucket is full or not in the correct position
DISPOSAL
This appliance may not be treated as regular
household waste, it should be taken to the
appropriate waste collection point for recycling of
electrical components. Check for local regulatory
compliance regarding approved and safe disposal
of this appliance.
7

Advertisement

Table of Contents
loading

Table of Contents