FlexGuard
®
FG-1625SN-ADT SIM Glassbreak Detector Installation Instructions
Refer to Supplemental Information (next page) for complete descriptions of these installation steps
FG-1625SN-ADT SIM Glassbreak Detector
Mounting Hole
Microphone
Bar Code
(serial no.)
DIP Switch
Mounting Hole
Front Cover
Cover Screw Location
Select Mounting Location
Wall Mount
(Top View)
Ceiling Mount: (Side View)
Test Location w/ 9V Battery
9V
Set Sensitivity Configuration
SENS1 & SENS2 configure sensitivity
SENSITIVITY
APPROXIMATE
RANGE
MAX
25 ft (7.6m)
MEDIUM
15 ft (4.6m)
LOW
10 ft (3m)
LOWEST
5 ft (1.5m)
Note: Ranges are approximate and vary with each
room's acoustic properties. Always verify range with a
FG-701 Glassbreak Simulator.
5-051-740-00A
Enable Wall Tamper / Pry-Off Switch
• Remove plastic tab from rear of detector.
• Install wall tamper screw as shown.
Tamper Switch
• Set screw depth to make contact w/ bottom of
Rear Tamper
tamper cavity when device is installed
Wire Entry Hole
Terminal Block
Test Mode Pads
LED Indicators
1625SN_001-V0
Connect Detector
Connect detector to the polling loop using 18 to 22 AWG
wire, with ends stripped approximately 6mm (1/4 inch).
Be sure to observe proper polarity!
1625_ceiling_mnt-001-V0
FG-1625SN-ADT SIM (Polling Loop) Wiring
Prepare Housing for Surface Wiring (Optional)
The back of the housing has four wire channels to
accommodate surface wiring. If surface wiring is to be
used, select the appropriate wire channel and remove
the breakout tab by inserting a flathead screwdriver
under the tab and prying upward.
1625SN_009-V0
SENS1
SENS2
Wire Channel
Breakout Tabs
Mount Detector
• Place unit over wall tamper screw, if used.
• Use mounting holes as template to mark ceiling or
SENS1
SENS2
wall.
• Mount detector using appropriate hardware.
OFF
OFF
NOTE: A screw capture feature designed to make
ON
OFF
ceiling mounting easier will cause some resistance
OFF
ON
when inserting the screw into the plastic.
ON
ON
1625Wiring_004-V0
Wire Channel
Breakout Tabs
Wire Channel
Breakout Tabs
1625SN_WireChan-V0
Page 1
Test Detector Installation
Enter Test Mode using FG-701 (see Testing the
Detector on the next page) or manually by shorting
Test Mode pads (as below). Test Mode will
automatically time out after five minutes.
IMPORTANT NOTE: Close Cover while testing.
Install Cover Screw (optional)
1625_008-V1
TEST