RF600 system planning
4.3 Antenna configurations
A A ntenna configuration 2
A A ntenna configuration 3
42
D D escription/ application areas
This arrangement of antennas is appro-
priate when the transponders to be read
are only located on one side of the items
to be identified, e.g. when pallets are to
be identified and it is known on which
side the transponders to be read are
located.
Transponder
D D escription/ appl l ication areas
Preferred for the identification of goods
at loading gates: The transponder is
located in the radiation field of two an-
tennas; for reliable transponder reading,
the height of the transponders above
floor level must therefore be known with
reasonable accuracy.
Transponder