Range When Mounted On Non-Metallic Carrier Materials - Siemens SIMATIC RF610T ATEX System Manual

Hide thumbs Also See for SIMATIC RF610T ATEX:
Table of Contents

Advertisement

Table 7- 20
C C arrie e r material
Metal plate at least 300 x 300 mm
Table 7- 21
C C arrier material
Metal plate at least 300 x 300 mm
The use of spacers on metallic surfaces is recommended.
On rectangular carrier plates, the range depends on the mounting orientation of the
transponder.
You will find more information on the range in the section "Minimum distances and maximum
ranges (Page 55)".
7 7 .7.3.2

Range when mounted on non-metallic carrier materials

Table 7- 22
Carrier material
Transponder on wooden carrier
(dry, degree of moisture < 15%)
Transponder on plastic carrier
Transponder on glass
Transponder on mineral water container
You will find more information on the range in the section "Minimum distances and maximum
ranges (Page 55)".
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
Range with metallic, flat carriers without spacers
Range with flat metallic carriers with spacers
Range with non-metallic carriers
R R ange
typically 40%
R R an n ge
typically 100%
Range
typically 75 %
typically 75 %
typically 75 %
typically 15 %
Transponder
7.7 SIMATIC RF620T