Zenith 42PX2D-UC Installation And Operating Manual, Warranty page 45

Table of Contents

Advertisement

Set ID
Set ID
Use this function to specify a monitor ID number.
Refer to 'Real Data Mapping'. See page 87.
1. Press the MENU button and then use
2. Press the
G
button and then use
G
3. Press the
button and then use
desired monitor ID number. The adjustment range of
4. Press EXIT button to return to TV viewing or press MENU button to return to the
previous menu.
Communication Parameters
Communication Parameters
• Baud rate : 9600 bps (UART)
• Data length : 8 bits
• Parity : None
* Use a crossed (reverse) cable.
Command Reference List
Command Reference List
COMMAND 1 COMMAND 2
01. Power
k
02. Input Select
k
03. Aspect Ratio
k
04. Screen Mute
k
05. Volume Mute
k
06. Volume Control
k
07. Contrast
k
08. Brightness
k
09. Color
k
10. Tint
k
11. Sharpness
k
12. OSD Select
k
13. Remote Control Lock Mode k
14. Treble
k
15. Bass
k
16. Balance
k
17. Color Temperature
k
18. ISM Method
j
19. Low Power
j
20. Orbiter Time Setting
j
21. Orbiter Pixel Setting
j
COM-
MAND 1
22. Channel Tuning
m
23. Channel Add/Del
m
24. Key
m
25. Input Select
x
button to select the
D / E
button to select
SET ID
D / E
D / E
button to adjust
SET ID
• Stop bit : 1 bit
• Communication code : ASCII code
DATA
(Hexadecimal)
a
0 ~ 1
b
0 ~ 9
c
*
d
0 ~ 1
e
0 ~ 2
f
0 ~ 64
g
0 ~ 64
h
0 ~ 64
i
0 ~ 64
j
0 ~ 64
k
0 ~ 64
l
0 ~ 1
m
0 ~ 1
r
0 ~ 64
s
0 ~ 64
t
0 ~ 64
u
0 ~ 2
p
*
q
0 ~ 1
r
1 ~ FE
s
1 ~3
COM-
DATA 0
MAND 2
(Hexadecimal)
(Hexadecimal)
a
physical/program high
major/program low
b
00 ~ 01
c
key code
*
b
menu.
SETUP
.
SET ID
to choose the
is 1 ~ 99.
T
ransmission / Receiving Protocol
T
ransmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1]: First command to control the set.(j,k,m or x)
* [Command 2]: Second command to control the set.
* [Set ID]: You can adjust the set ID to choose desired monitor
ID number in Setup menu. Adjustment range is 1
~ 99. When selecting Set ID '0', every connected
the TV is controlled. Set ID is indicated as decimal
(1~99) on menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
* [DATA]: To transmit command data.
Transmit 'FF' data to read status of command.
* [Cr]: Carriage Return
ASCII code '0x0D'
* [ ]: ASCII code 'space (0x20)'
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving abnormal data from non-viable
functions or communication errors.
Data 1: Illegal Code
2: Not supported function
3: Wait more time
DATA 1
DATA 2
DATA 3
(Hexadecimal)
(Hexadecimal)
major low
minor high
External Control Device Setup
DATA 4
DATA 5
(Hexadecimal)
(Hexadecimal)
minor low
attribute
Owner's Manual 45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z42px21dZ42px2d42px21d-ucDu42px20

Table of Contents