12.8 Installation
Checking the unit
Check whether the fitted unit is level and has suffi-
1.
cient load-bearing capacity.
The max. weight of the appliance is 18 kg.
Ensure that the fitted unit is heat-resistant up to
2.
90 °C.
Ensure that the fitted unit is still stable after the cut-
3.
outs have been made.
4.
Ensure that the fitted unit complies with the following
dimensions:
Width
Depth
Position
Wall thickness
Preparing the units
Requirement: The unit is suitable for the
→ "Checking the unit", Page 13 installation.
Cover the hob to prevent damage.
1.
Ensure that the stability of the fitted unit is guaran-
2.
teed after the cut-outs have been made.
If the cabinet is more than 310 mm deep, remove
3.
part of the back panel.
Create the cut-out for the pipe connection.
4.
If the cabinet base is in place, remove it.
5.
Remove any shavings.
6.
Use the enclosed mounting part to mark the fasten-
7.
ing points on the inside of the cabinet and use a
bradawl to make indentations where the holes are
to be.
600 mm
Min. 320 mm
With lowering frame:
Min. 350 mm
Min. 390 mm
With CleanAir circulat-
ing-air set, min. 600 mm
16 mm or 19 mm
19 mm wall thickness: Open up the spacers on
8.
both of the mounting parts.
Screw the mounting parts to the body on the left
9.
and right.
Remove the limit stops from the bottom of the
10.
mounting parts.
Preparing the appliance
Insert the holders for the wall edging strip on the
1.
outside rear of the appliance into the cut-outs and
fold them in to the centre of the unit.
Connect the enclosed power cord to the appliance
2.
and secure the stain relief.