Mitsubishi Electric MUZ-D-NA Series Service Manual page 34

Indoor unit
Table of Contents

Advertisement

OPERATING PROCEDURE
6. Removing the line flow fan and the indoor fan motor
(1) Remove the panel and the corner box. (Refer to 1.)
(2) Remove the electrical box. (Refer to 2.)
(3) Remove the nozzle assembly. (Refer to 3.)
(4) Remove the water cover.
(5) Loosen the screw of the line flow fan.
(6) Remove the screws of the motor bed.
(7) Remove the lead wire of the indoor coil thermistor from the
hooks of the motor bed.
(8) Remove the motor band and the motor bed together with
indoor fan motor. (Be careful not to drop the indoor fan
motor because it is heavy.)
(9) Remove the screw of the motor band, and remove the
motor band then pull out the indoor fan motor.
(10) Remove the screws of the left side of the heat exchanger.
(11) Lift the left side of the heat exchanger.
(12) Remove the line flow fan to the lower-left.
Photo 9
Copyright 2008 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD
Distributed in Apr. 2011. No. OBH501 REVISED EDITION-C
Distributed in Jun. 2008. No. OBH501 REVISED EDITION-B 6
Distributed in Mar. 2008. No. OBH501 REVISED EDITION-A 7
Distributed in Feb. 2008. No. OBH501 7
Made in Japan
Screw of the line
flow fan
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
PHOTOS
Photo 7
Photo 8
Screws of the left
side of the heat
exchanger
New publication, effective Apr. 2011
Specifications subject to change without notice.
Screw of the motor band
Screws of the motor bed
Lead wire of the indoor
coil thermistor