Chicago Electric 99702 Set Up And Operating Instructions Manual page 14

Airless paint spray machine
Table of Contents

Advertisement

mAintenAnce And
serVicing
Procedures not specifically
explained in this manual
must be performed only by a
qualified technician.
FrOm AccidentAl
OperAtiOn:
turn the power switch of the
tool to its "OFF" position and
unplug the tool from its
electrical outlet before
performing any inspection or
maintenance.
tO preVent seriOus
injury FrOm tOOl
FAilure:
do not use damaged
equipment. if abnormal noise
or vibration occurs, have the
problem corrected before
further use.
cleaning, maintenance, and
lubrication
1.
BeFOre eAch use,
general condition of the tool. Check
for loose screws, misalignment or
binding of moving parts, cracked or
broken parts, damaged electrical wir-
ing, and any other condition that may
affect its safe operation.
AFter use,
2.
clean the sprayer and components
with clean water. When using oil
based paint, use mineral spirits to
clean the sprayer and components.
SKU 99702
tO preVent
seriOus injury
inspect the
When using latex paint,
For technical questions, please call 1-800-444-3353.
a.
Lock the Gun and remove the Spray
Tip assembly.
b.
Submerge the Suction Tube in a
container with the appropriate clean-
ing solution.
c.
Place the waste material container
next to the paint container.
d.
Aim the Spray Gun into the paint
container and pull the trigger.
e.
Turn the Power switch to the "ON"
position and the "PRIME/SPRAY"
knob to "SPRAY". Purge the paint
into the original container until the
cleaning solution starts coming out.
f.
Move the Spray Gun to the waste
container and continue holding the
Trigger down until the cleaning fluid
coming out is paint-free.
g.
Release the Trigger, turn the
"PRIME/SPRAY" knob to "PRIME"
and pull the trigger once to release
pressure.
h.
Turn the power switch of the unit
"OFF" and lock the Gun.
i.
Remove the Suction Hose and re-
turn tube and clean them.
j.
Wipe the thread of the inlet nut and
remove and clean the inlet filter.
k.
Thread the suction tube back in
place and reconnect the return tube
onto the return tube fitting.
l.
Submerge the suction set in a con-
tainer of NEW cleaning solution.
m.
Turn the "PRIME/SPRAY" knob to
"PRIME" and squeeze the trigger
once into the waste container to
relieve pressure.
n.
Allow the pump to circulate the
cleaning solution through the suction
set for three minutes. If oil based
paints were used, the unit must
Page 14