Unless otherwise noted, references to brand names, product names, or trademarks constitute the intellectual property of the owner thereof. Subject to your right to use the unit, Compac does not convey any right, title, or interest in its intellectual property, including and without limitation, its patents, copyrights, and know-how.
This is not a recommended alternative to wearing an anti-static wrist strap. Note: Compac Industries Limited reserves the right to refuse to accept any circuit boards returned, if proper anti-static precautions have not been taken.
Triac Dip-switches Important note: Great care should be taken not to accidentally change the setting of these switches while working in the Flame-proof box. Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the solenoid. These switches are set in the factory and should not be changed.
Electrical Connections Prior to pump installation ensure that there is at least a two-metre tail on the incoming underground mains supply / pump contactor cable and comms cable (if comms enabled). These cables are terminated at the C4000 power supply, which is housed in the flameproof enclosure located in the bottom of the pump, behind the door.
Dispensing Hoses and Nozzles The unit may or may not be supplied with dispensing hose and nozzle assemblies. If customer supplied hose assemblies, pylons, reels, safe breaks and nozzles are used they must comply with the requirements outlined in AS/NZS 222. Breakaways Any breakaway couplings that have been subject to a break-away situation should be inspected and refitted or replaced in accordance with the original manufacturer’s instructions.
Configuration Codes 12.1 The configuration code has been set at Compac and should not be changed In the event of it being lost and having to be re-entered the configuration is written on the yellow label on the C4000 processor board cover...
This is the time delay from when the Submersible pump starts to when the solenoids in the dispenser open to allow time for the leak detector to reset. This is factory set by Compac at 005 (five seconds). If problems are experienced with the leak detector tripping, firstly check that 'Sd' is still set and then, if necessary, make it longer as follows.
Parameter Switch settings 12.4 12.4.1 Setting the Pump Number This must be set at the pump, for each hose, so that communications with a controller can take place. The location of this switch is shown in the diagram below. Depress the Parameter Switch nine (9) or more times until the message 'PnA XX' appears in the litres display window.
K-Factor Switch Settings 12.5 K-Factor, and other various configuration settings, are set via this switch. The position of the K- Factor switch is shown in the diagram below: Parameter Switch K factor K Factor Switch Switch Parameter Switch J1: Comms Test J7: Displays J13: Not used J2: To Power Supply...
Calibration (K-Factor) Setting the K-Factor 13.1 K-Factor is a proportional calibration factor of litres dispensed per revolution of the meter. To calibrate the dispenser/pump, dispense fuel into a certified measuring container, and compare the display value with the amount dispensed. Example: Display shows 10.00 True volume...
Standalone Operation 13.3 In standalone operation, the dispenser will continue working when not connected to a controller. 'Stand-alone' mode being when no authorisation of fills is required and so fills are simply initiated by removing the refuelling assembly from its holder. If standalone operation is inhibited, the dispenser will not work in 'stand-alone' mode, regardless of whether the dispenser is ON LINE to a controller or not.
Error Messages Error Code Fault Action Err 3 No price or pump number set. Set the pump number or: Set a price at the pump or at the controller. Err 7 Excess flow. Max Flowrate exceeded Err 8 Excess reverse rotation of encoder. Check product is not flowing back into the tank once the delivery has finished.
MR400S Spare Parts Commercial Display (as shown – includes backlighting) F-CP-DISPLAY-CMH Retail display (includes backlighting) not shown F-CP-DISPLAY-GD1H Tote F-BA-TOTE-A-K C4000 Microprocessor Board F-CP-C4PROCES-A Nozzle Holder For Banlaw nozzle only P-NOZL-HLDR-BNLW COM250 meter (complete) F-METER-COM250AS COM250 meter (electronics) F-METER-125/250E Solenoid P-SOLND-S50-E321 C4000 Power Supply (does not include box)
Revision History Previous revision date Summary of changes 22 May 2009 Added contact details and revision history, updated spare parts 29 July 2009 Amended footprint drawing to show two possible footprint options. 26 June 2011 Added installation text 06 June 2012 Added Conditions of Use.