Unless otherwise noted, references to brand names, product names, or trademarks constitute the intellectual property of the owner thereof. Subject to your right to use the unit, Compac does not convey any right, title, or interest in its intellectual property, including and without limitation, its patents, copyrights, and know-how.
This is not a recommended alternative to wearing an anti-static wrist strap. Note: Compac Industries Limited reserves the right to refuse to accept any circuit boards returned, if proper anti-static precautions have not been taken.
These switches are set in the factory and should not be changed. If they are accidentally changed these are the correct settings for Master / Premier Dispenser applications.Note: They are 3 position switches Dispenser (low current output) \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 6 of 16...
If both sides are required to switch the same submersible pump then T1 and T4 should be linked together. Note: Dispensers do not use the terminals marked LOAD 1 & 2. \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 7 of 16...
Configuration Codes The configuration code has been set at Compac and should not be changed In the event of it being lost and having to be re-entered the configuration is written on the yellow label on the C4000 processor board cover.
The price for side ‘B’ is shown as ‘PX.XXX’ on the times in quick succession litres display and ‘Prb’ is displayed on the money display. Repeat steps 3 to 5 above. \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 9 of 16...
J15: Not used Side A J4: Input from KG Meter J10: Totes J16: Not used Side B J5 : Not Used J11: Buzzer J17 Backlighting J6 Not used J12 Nozzle Switches \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 10 of 16...
Factor 10.00 Existing Factor Change the existing 'K' Factor to this new value. Sealing the K-Factor switch 10.2 After calibration the K-factor switch should be sealed as shown \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 11 of 16...
3) For units where the generator starts and stops on demand, install a delay timer or PLC to automatically isolate the unit until the operating speed and consistent power output is achieved. 4) Isolate the unit before shutting down the generator. \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 12 of 16...
& interface PCB) F-FAS-PSET-MEM Solenoid spare parts Coil - F-SOL-20P1-COIL Main body kit - F-SOL-20P1-MBKT Top body kit - F-SOL-20P1-TBKT Always quote model and serial number when ordering spare parts. \\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MMR160S Installation Sheet.doc Page 14 of 16...