TROUBLESHOOTING

If you have any problems during using this product, please check the following point first.
If a problem cannot be solved by taking actions described below, unplug the battery charger and
contact the dealer or an authorised TOSHIBA TEC service representative for assistance
Symptom
A battery pack is loaded in the
battery charger, but the CHARGE
lamp does not light up in red
The CHARGE lamp blinks in red.
Charging time overruns the
approximate specified time.
Battery does not last long time
though the battery is fully charged.
The battery pack cannot be inserted
into the slot.
Cause and resolution
• The power cord or AC adapter is not connected properly.
⇒ Firmly connect the power cord or AC adapter.
• The terminals of the battery charger or the battery
electrodes are stained.
⇒ Wipe clean those portions with a soft dry cloth.
• You are attempting to charge a battery pack with the over
discharge protection activated (The CHARGE lamp may not
light up immediately after loading a battery.)
⇒ Leave the battery charger and the battery pack alone
for a few minutes. If the CHARGE lamp does not light after
all, stop using the battery pack, as the battery pack may
be faulty.
• The partition is not fitted.
⇒ Fit the partition in the correct orientation.
• A battery pack failure is detected.
⇒ It could be the end of battery life. Replace the battery
pack with a new one.
• Charging time varies depending on the condition of the
battery pack, ambient temperature, etc.
⇒ If the battery charger continues charging even after the
specified time has passed, stop charging and replace
the battery pack with a new one.
• It could be the end of battery life.
⇒ Replace the battery pack with a new one.
• The partition is not set completely.
⇒ Fit the partition completely.